Owner's manual

Opticon Ethernet Converter - 7
2.2.1 Method 1: Using the System menu via RS232
Connect your Ethernet Converter box to the serial port of a PC or Laptop and open an RS232 monitor (i.e.
Hyperterminal or Appload) using the following serial settings:
ยง 115200 baud (8 data bits, no parity, 1 stop bit)
Enter the system menu by powering up the Ethernet box with the set-up button pressed. After that, the following
menu will be shown:
1: Show current settings.
2: Change Board Host Name.
3: Change default IP address.
4: Change default gateway address.
5: Change default subnet mask.
6: Change default DNS server address.
7: Enable DHCP.
8: Disable DHCP.
0: Save & Quit
Enter a menu choice (1-0):
While being in the system menu, pressing the corresponding numbers will give the following results:
1: Show current settings
Settings of the OSE Ethernet-to-RS232 Converter Box
Version: HACV0010
MAC Address: 00-12-6A-xx-xx-xx
Local IP Address: 169.254.254.254
Gateway Address: 169.254.254.1
Subnet mask: 255.255.0.0
DNS server address: 169.169.169.2
DHCP: Enabled
Baudrate: 115200
2: Change Board Host Name
Host Name (OSE_ETHERNETBOX): <enter new host name>
3: Change default IP address
Default IP Address (169.254.254.254): <enter IP address>
4: Change default gateway address
Default Gateway Address (169.254.254.1): <enter IP address>
5: Change default subnet mask
Default Subnet Mask (255.255.0.0): <enter IP Mask>
6: Change default DNS server address
Default DNS Server Address (169.169.169.2): <enter IP address>
7: Enable DHCP
DHCP Enabled.
8: Disable DHCP
DHCP Disabled.
0: Save & Quit
Now running application...
Pressing of set-up button for 4 seconds
All settings have been restored to default. Press '0' to cancel, remove power to confirm.