8.3 Drop Impact Strength (without packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop the scanner 12 times in total (2 times at the 6 positions as indicated) from a height of
150 cm onto a concrete floor.
Figure 10: Drop test
8.4 Drop Impact Strength (in individual packaging)
There shall be no sign of malfunction after the following drop test.
Drop test: Drop an individually packaged scanner 10 times in total, at any of 1 corner, 3 edges, and 6
faces, from a height of 150 cm onto a concrete floor.
8.5 Electrostatic Discharge (ESD) Immunity
Contact discharge
±6 kV max (direct or indirect discharge, no malfunction)
Aerial discharge
±8 kV max (no malfunction)
±15 kV max (no destruction)
Measurement environment
Testing method compliant with IEC-61000-4-2.
Discharge resistance
330 Ω
Charging capacitor
150 pF