User's Manual
Table Of Contents
- 1. Abstract
- 2. Overview
- 3. Physical Features
- 4. Environmental Specifications
- 5. Controls
- 6. Electrical Specifications
- 7. Optical Specifications
- 8. Technical Specifications
- 9. Interface Specifications
- 10. Serial Number
- 11. Packaging Specifications
- 12. Durability
- 13. Reliability
- 14. Regulatory Compliance
- 15. Safety
- 16. Mechanical Drawing
Opticon
OPL-9813
Specifications Manual
12. Durability
12.1. Drop Test (without packaging)
No malfunction occurred after the following drop test.
Drop Test: Drop the data collector from a height of 150 cm onto a concrete floor. Each
side of the data collector impacted the floor three times.
Figure 11: Drop test
12.2. Dust and Drip Proof
IEC IP54
Dust Prevention
Level Details
5
Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere
with the satisfactory operation of the equipment; complete protection against contact.
Water Prevention
Level Details
4 Water splashing against the enclosure from any direction shall have no harmful effect.
21