User's Manual

Table Of Contents
Opticon
OPL-9813
Specifications Manual
Resolution Symbology PCS Quiet Zone Digit
1.0 mm Code 39 0.9 25 mm 1
0.5 mm Code 39 0.9 18 mm 3
0.25 mm Code 39 0.9 10 mm 8
0.15 mm Code 39 0.9 7 mm 10
Note: dirt or scratches on the mask will degrade scanning performance. Always
handle the data collector carefully.
8.4. Pitch, Skew, and Tilt
8.4.1. Pitch Angle
α = ±2
Figure 3: Pitch
Conditions
Barcode Sample: OPTOELECTRONICS Test Sample
Distance: 90 mm from the edge of the data collector
Label:
Pitch, Skew Angle
PCS = 0.9, Resolution = 0.25 mm, Symbology = 9-digit Code 39,
Quiet Zone = 10 mm, N/W Ratio = 1:2.5
Dead Zone, Tilt Angle
PCS = 0.9, Resolution = 0.26 mm, Symbology = 13-digit JAN, Quiet Zone = 10 mm
Angle: Curvature: R = ∞, Skew Angle = β +15° (for measuring Pitch Angle and Tilt Angle)
12