User's Manual

Opticon user's manual
USERS MANUAL PHL2700 TERMINAL / IRU2700 CRADLE
19
Transmission speed RS232 direct cable:
2400 - 115200 baud
RS232 cradle:
2400 - 115200 baud
IrDA terminal:
2400 - 115200 baud
6.1.5
Environmental specifications
Temperature 0 - 50
o
C in operation
-10 - 60
o
C in storage
Humidity 20 - 80 % in operation
(non condensing) 20 - 90 % in storage
Shock: drop: 1.5 m drop onto concrete surface
Shock: vibration: 10 - 50 Hz with 1G for 30 min,
cycle for X,Y,Z.
Ambient light fluorescent 3.000 lux max.
rejection direct sun 50.000 lux max.
Emission According to EN50081, part 1
Immunity According to EN50082, part 1
Protection against
dust and moisture According to IEC529, IP 42
Safety, Laser class According to IEC825,
Class I laserproduct
6.1.6
Supported symbologies
Chinese Post 2of5
Codabar incl. ABC and CX
Code 39
Code 93
Code 128
EAN-8 incl. +2,+5
EAN-13 incl. +2,+5
IATA
Industrial 2of5
Interleaved 2of5
Italian Pharmaceutical
Laetus
Matrix 2of5
MSI/ Plessey
UK/ Plessey
S-Code
Telepen
UPC-A incl. +2,+5
UPC-E incl. +2,+5
6.2.1
Electrical specifications
Battery charging time when battery in terminal:
8 hours charge
6.2.2
Functionality
Interfaces supported RS232
RS485
Serial communication RS232 Baudrate:
1200 - 115200
RS485 Baudrate:
1200 - 115200
Transmission modes Half duplex RS232
Half duplex RS485
Parity Odd, Even, None
6.2.3
Environmental specifications
Temperature 0 - 40
o
C in operation
-20 - 60
o
C in storage
Humidity 30 - 85 % in operation
(non condensing) 30 - 90 % in storage
Shock: vibration: 10 - 50 Hz with 1G for 30 min,
cycle for X,Y,Z.
Emission According to EN50081, part 1
Immunity According to EN50082, part 1
6.2.4
Physical specifications
Dimensions (l x w x d) 150 x 90 x 81 mm
Case material ABS
Weight 250 g
Standard connector RS232 - D Sub 9P Female
RS485 - 6 pins modular plug
USERS MANUAL PHL2700 TERMINAL / IRU2700 CRADLE
18
6.1.1
Electrical specifications
Main battery rechargeable pack: Ni-MH
dry cell: Alkaline penlite
optional: other 2 x AA-size
penlite
Main battery Ni-MH: When making every 5
operating time seconds 1 scan with 1 sec
laserbeam on and 0.2 sec.
green LED on and 0.2 sec.
buzzer on, operating time is:
approx. 40 hours
Alkaline: When making every
5 seconds 1 scan with 1 sec
laserbeam on and 0.2 sec.
green LED on and 0.2 sec.
buzzer on, operating time is:
approx. 78 hours
Different operation conditions
affect the operating time
Use of other penlite batteries
affect the operating time
Backup battery Lithium (CR2032)
Backup battery If fully charged: 30 days backup
operating time time
Battery Low voltage indicated on the
management terminal display.
When battery is low the
terminal switches off
automatically.
Charging method Rechargeable Ni-MH pack in
terminal via cradle
6.1.2
Optical specifications
Light source 650 nm visible laser diode
Scan rate 100 scans/sec
Decode rate 100 decodes/sec
Reading width 62 mm at 30 mm
111 mm at 100 mm
Resolution
at PCS 0,9 0.15 mm (6mil)
Depth of field 0 - 140 mm
(at PCS 0.9, res. 0.25)
6.1.3
Physical specifications
Dimensions (l x w x d) 177 x 62 x 41 mm
Case material ABS
Weight body (excl. battery): 175 g
Direct cable (optional) RS232 - DB9 female
6.1.4
Functionality
Memory ROM: 32 kB
FlashROM (for O/S and
program): 512 kB
fast RAM: 2kB
battery backed up D-RAM
(for data): 8 MB
Microprocessor 16-bit
Real time clock Quartz RTC, time and date
programmable, leap year
handling, (accuracy +
60
sec./month)
Display 128x64 Pixels graphic LCD
with backlight Character fonts:
4/8 lines x 16 characters
5/10 lines x 21 characters
Keyboard 27 keys total
(26 keys user definable)
8 Function keys
Alpha/Numeric mode
Trigger mode Manual
Programming Functionality is provided by
user application. The application
may be downloaded from PC
via cable, com port or IrDA.
Interfaces supported RS232 by direct cable
RS232 by cradle
IrDA on terminal
SPECIFICATIONS
3
6
6.1 SPECIFICATIONS TERMINAL