Quick Guide
Outdoor detection range
Indoor detection range
Beam
Beam blocking ratio
4ch. selectable freq.
Alignment angle
LED indicator
Monitor jack for align.
Beam alignment method 
Automatic gain control
Lightning protection
Environment DQ
Power supply
Current draw (Peak)
Alarm output
Tamper
Alarm memory
Anti-frost design
Optional heating unit
International protection
Operation temperature
Environmental humidity
Dimensions (HxWxD in)
100
200
620μA
200
400
200
400
100
200
Twin
99%
3
+/- 90˚ Horiz., +/- 5˚ Vert
4step LED indicator
3
No
Yes, Wirefree operation
3
3.6V 13.0Ah LSH20
 lithium batteries (4 included)
FormC
3
—
3
HU-3, Requires local power
IP55
-4° to 140°F (-20 to 60˚C)
95% max.
8.5 x 3.5 x 6.4
Twin
99%
3
+/- 90˚ Horiz., +/- 5˚ Vert
4step LED indicator
3
No
Yes, Wirefree operation
3
3.6V 13.0Ah LSH20 lithium batteries 
(For Hybrid: 2 included for Transmitter Unit)
FormC
3
—
3
HU-3, Requires local power
IP65
-4° to 140°F (-20 to 60˚C)
95% max.
11.6 x 2.7 x 4.6
Quad
99%
No
+/- 90˚ Horiz., +/- 10˚ Vert
4step LED indicator
3
No
3over14kV
No
Form C relay : 30VDC, 0.2 A
3
—
3
HU-3
IP65
-31° to 140°F (-35 to 60˚C)
95% max.
17.6 x 3.1 x 3.8
Quad
99%
3
+/- 90˚ Horiz., +/- 10˚ Vert
5 Step with sound assist
3
3
3over14kV
3
Form C relay: 30 VDC, 0.2 A
3
—
3
HU-3
IP65
-31° to 140°F (-35 to 60˚C)
95% max.
17.6 x 3.1 x 3.8
Quad
99%
3 
+/- 90˚ Horiz., +/- 10˚ Vert
5 Step with sound assist
3
3
3over14kV
3
Form C relay: 30 VDC, 0.2 A
3
—
3
HU-3
IP65
-31° to 140°F (-35 to 60˚C)
95% max.
17.6 x 3.1 x 3.8
350
700
39mA max.
650
1300
40mA max.
200
400
38mA max.
350
700
650
1300
350
700
650
1300
200
400
ViewfinderViewfinder Sniper viewfinder 
TM
Sniper viewfinder (Included) / BAU-4 Beam Alignment Unit (Optional) 
350
700
Quad
99%
3
+/- 90˚ Horiz., +/- 5˚ Vert
4step LED indicator
3
No
Yes, Wirefree operation
3
3.6V 13.0Ah LSH20
 lithium batteries (4 included)
745μA
FormC
3
—
3
HU-3, Requires local power
IP65
-4° to 140°F (-20 to 60˚C)
95% max.
17.9 x 3.3 x 5.4
Trenching is too expensive
Trenching is not an option
Power is not available
Double stacking is needed
Long distance is required
DQ Circuit is needed
SL-350QFR
SL-350QFRi
AX-100TFR AX-100TFRi
Includes 
Inovonics 
EN1941 
transmitter
and batteries
Includes 
Inovonics 
EN1941 
transmitter
and batteries
Includes 
Inovonics 
EN1941 
transmitter
and batteries
Includes 
batteries
Includes
batteries
Includes
batteries
AX-200TFR AX-200TFRiSL-100TNR SL-100TNRi
Includes 
Inovonics 
EN1941 
transmitter
and batteries
Includes 
Inovonics 
EN1941 
transmitter
and batteries
Hybrid
Powered
Hybrid
Powered
SL-200TNR SL-200TNRi
USE THIS BEAM IF
Trenching is too expensive
Trenching is not an option
Power is not available
Double stacking is needed
Shorter distance is required
DQ Circuit is needed
USE THIS BEAM IF
One beam unit is close to main power source
but other beam unit needs to be wireless
Power is not available
Shorter distance is required
DQ Circuit is needed
USE THIS BEAM IF
Power to both sides is avail.
Long distance is required
Double stacking/long runs needed
Harsh environment at site
A.T.P.C. feature is needed
Better false alarm immunity
USE THIS BEAM IF
200
400
Power to both sides is avail.
Long distance is required
Double stacking/long runs needed
Harsh environment at site
Manual beam power adjust. needed
DQ Circuit is needed
USE THIS BEAM IF
Power to both sides is avail.
Shorter distance is required
Double stacking is not necessary
Multiple sets are not used
USE THIS BEAM IF
6’6” TOWERS
AX-TW200
AX-TW200S
AX-TW200M
AX-TW100
AX-TW100S
AX-TW100M
Double Sided, Free Standing
3’3” TOWERS
40mA max. 43mA max.24mA max. 33mA max.
10.5 - 30V DC 10.5 - 28V DC 10.5 - 28V DC
PIE-1
PoE IP Encoder
Advanced Models Professional Models
Allows beams to 
connect / integrate 
with all leading VMS 
platforms to control 
IP cameras (should 
be ordered in pairs)
Prevents birds and 
small animals from 
sitting on detector. 
Also protects the 
front of detector 
from excessive rain 
and snow.
ABC-4 
Anti-Bird Cap
HU-3
Heating Unit
Heating Unit for 
Hardwired SL 
Models and AX-TN, 
AX-TF Models.
Conceals the back 
side of a pole 
mounted SL Series 
detector.
CBR-4 
Conduit Bracket
Required to run 
conduit to the SL 
Series detectors.
BC-4 
Back Cover
PSC-4
Pole Side Cover
Conceals the gap 
between two pole 
mounted, back to 
back SL Series 
detectors.
SL-200QN SL-350QN SL-650QN SL-200QDP SL-350QDM SL-650QDMSL-350QDP SL-650QDP SL-200QDM
Hybrid, Battery-Powered, & Wireless Options
ENCLOSURES
( ) =
Single Sided, Free Standing
(S) =
 Single Sided, Wall Mount
(M) = 
Standard Models Advanced Models Professional Models
810μA600μA500μA
800.966.7839
sales@optexamerica.com
www.optexamerica.com
 @optexamericafacebook.com/
optexamerica
linkedin.com/
company/optex