INSTALLATION GUIDE

- 5 -
5
Mount the IVPC-DS
Battery operation
Wired operation (New installation); 10 to 24 V AC/DC
Fix the mounting plate.
Attach the
main unit.
Slide down.
Remove the back
cover.
Wire the power cables.
Replace the back
cover. *1
Fix the mounting
plate.
Attach the
main unit.
Slide down.
<<
Battery charging
>>
Micro USB port
(For battery charging)
- Charging not needed for wired operation.
- Use the included USB cable with any USB
port power supply or charge station capable
of delivering 5 V DC at 1A or greater.
- Full charge time will be approximately 10 hours.
Please recharge only when temperature is +10°C to + 40°C.
(+50°F to +104°F)
Tighten the lock screw.
- Choose battery or wired operation.
1
2
3
1
2
1 2 3
Tighten the lock screw.
1
2
4
5 6
- See “Retrofit wiring” on the next page, if replacing an existing door chime.
Make sure to turn
off power.
! Caution
NOTE
Polarity is not a concern.
*1 The back cover protects against water intrusion. Make sure nothing is interfering with it.
*2 If the power source is kept off, the IVPC-DS is driven by the inner battery.
It may cause unexpected system shutdown if power is not restored before the battery depletes.
USB port: 5 V 1 A or greater power supply
ON
OFF
7
8
Turn on power. *2
Mount the main unit.
Assemble the main unit.
! Caution