Installation Manual

【AX-70/130/200TN, AX-100/200TF】
【BC-3】 【PSC-3】 【HU-3】
Name Photoelectric detector
Model AX-70TN AX-130TN AX-200TN AX-100TF AX-200TF
Range 70ft (20m) 130ft (40m) 200ft (60m) 100ft (30m) 200ft (60m)
Maximum arrival distance
700ft
(200m)
1300ft
(400m)
2000ft
(600m)
1000ft
(300m)
2000ft
(600m)
Detection method Infrared beam interruption detection
Selectable beam frequency 4 channel
Interruption period Variable between 50,100,250,500msec (4 steps)
Power input 10.5-28VDC
Current draw
(Transmitter+Receiver)
38mA (max.)
T:17mA+R:21mA
41mA (max.)
T:20mA+R:21mA
45mA (max.)
T:24mA+R:21mA
44mA (max.)
T:6mA+R:38mA
48mA (max.)
T:10mA+R:38mA
Output
Alarm output N.C. 28VDC, 0.2A (max.)
N.C./ N.O.
28VDC, 0.2A (max.)
Alarm period 2 sec (±1) nominal
D.Q.output N.C. 28VDC, 0.2A (max.)
Tamper output N.C. : open when cover is removed 28VDC, 0.2A (max.)
Indicator
Alarm indicator
(Receiver)
Alarm : ON (red), Light receiving : OFF
Alarm : ON (red)
Light receiving : icker (red) or OFF
Power
(Transmitter)
Power ON : ON (green), Power OFF : OFF
Alarm memory
Memory : ON or icker (red)
(Indicator will remain lit for 55 minutes,
5 minutes after alarm output)
Operating temperature
–31°F– +140°F (–35– +60
)
Use the optional heating unit (HU-3) under the environment of
–13°F (–25
) or less minus.
Environment humidity 95% max
Alignment angle ±90°Horizontal, ±5°Vertical
Mounting Indoor/Outdoor, Wall/Pole mounting
Weight 22.9oz (650g) 24.7oz (700g)
International protection IP65
Packages
Transmitter (
×
1), Receiver (
×
1), Pole bracket (
×
4), Mounting plate
lock screws (
×
8),Pole lock screws (
×
8), Wall mounting screws (
×
4)
Name Heating unit
Model HU-3
Power input 24VAC/DC
Current draw 420mA(max.)
(Per 1 unit)
Thermo
switch
140°F (60
)
Operating
temperature
–31°F– +140°
F
(–35– +60
)
Weight 0.4oz(12g)
(Heater (
×
2))
Packages
Heater (
×
2), Connector
(
×
4), Waterproof agent
Name Back cover
Model BC-3
Operating
temperature
–31°F– +140°
F
(–35– +60
)
Weight 5.3oz(150g)
(Back Cover (
×
2))
Packages Back cover (
×
2),
Optional pole bracket
(
×
4), Back cover lock
screw (
×
8)
Name Pole side cover
Model PSC-3
Operating
temperature
–31°F– +140°
F
(–35– +60
)
Weight 3.9oz(110g)
(Pole Side Cover (
×
2))
Packages Pole side cover (
×
2),
Optional pole bracket
(
×
4), Pole side cover
lock screw (
×
8)












QTQXGT







QTQXGT
ǾǾ㧦ǾǾ㧦



#EVWCNNGPIVJ

10. SPECIFICATIONS
< note >
These units are designed to detect an intruder and activate
an alarm control panel. Being only a part of a complete
system, we cannot accept responsibility for any damages
or other consequences resulting from an intrusion.
These products conform to the EMC Directive 89/336 ECC.
The diameter of a pole :
minΦ1.3(Φ32)-maxΦ1.9(Φ48)
The diameter of a pole :
minΦ1.3(Φ32)-maxΦ1.9(Φ48)
Unit : inches (mm)
OPTEX INCORPORATED (USA)
TEL:+1-909-993-5770
Tech:(800)966-7839
URL:http://www.optexamerica.com
OPTEX CO., LTD. (JAPAN)
(ISO 9001 Certified by LRQA)(ISO 14001 Certified by JET)
5-8-12 Ogoto Otsu Shiga 520-0101 JAPAN
TEL:+81-77-579-8670 FAX:+81-77-579-8190
URL:http://www.optex.co.jp/e/
OPTEX (EUROPE) LTD. (UK)
TEL:+44-1628-631000
URL:http://www.optexeurope.com