Installation Manual

1. Cutout of the knockout
Cut off the knockout portion of the back cover
with a cutter, etc.
Back Cover
2. Installation of mounting plate
Fix the unit base body mounting-plate
and the pole bracket for the option sup-
plied with the back cover by using the
supplied screws.
Optional
pole bracket
(for BC-3)
Mounting plate
lock screws
(for main unit)
Pole lock screws
(for main unit)
3. Installation of the unit base and the
back cover
After mounting the units base, x the back cover on
the pole bracket by using the screws (4 pieces).
Align the optical axis and check for the operation,
then close the cover. (See “ 3. INSTALLATION “)
8-2 BACK COVER : BC-3
8-3 POLE SIDE COVER : PSC-3
Cut the edge of the knockout (outside or inside) with a
nipper and then break the knockout portion with a cutter.
Also break the center bridge of the pole side cover
along with the perforation.
1. Cutout of the knockout 2. Installation of the pole side
covers
3. Installation of the pole
side covers
Pole Side Cover
Outside of the knockout (φ35-48mm : the diameter of a pole)
Inside of the knockout (φ32-34mm : the diameter of a pole)
Knockout
(The same
applies to the
opposite side.)
Back cover lock screw
(The same applies to
the opposite side.)
Unit Base
9. TROUBLE SHOOTING
Problem Possible Cause Corrective Action
LEDs on the transmitter are not
illuminated.
Inappropriate power supply voltage Check the voltage and make sure that it is between 10.5 and 28VDC.
Disconnection in power line Check the wiring
Inappropriate wiring distance or wire diameter
See "2. Wiring distance between power supply and detector" of "4. WIRE
CONNECTIONS", and check the wiring distance.
"Alarm Indicator" is not iiluminated
even if the beam is blocked in front of
the receiver.
Inappropriate power supply voltage Check the voltage and make sure that it is between 10.5 and 28VDC.
Inappropriate wiring distance or wire diameter
See "2. Wiring distance between power supply and detector" of "4. WIRE
CONNECTIONS", and check the wiring distance.
The beams are re ecting off the oor and
wall of a building, and entering the receiver.
Align the optical axis again. If "Alarm Indicator" is not turned on yet,
remove the re ecting objects or change the installation site.
Not interrupting both upper and lower beams at the
same time.
Interrupt both upper and lower beams at the same time.
Receiving any other beams from other transmitters.
Move the receiver to any other place where it does not receive any beam
from other transmitters.
Blocking the beam in fron to fot
the receiver illuminates the "Alarm
Indicator" but does not activate the
alarm.
Signal line short-circuited Check the wiring
Alarm contact welded Repair the required. Contact the distributor or us.
"Alarm Indicator" of the receiver does
not go out.
Optical axis of transmitter and receiver not aligned. See "5-1 OPTICAL ALIGNMENT" and make realignment.
Object blocking the beam between transmitter and receiver
Remove the object or move the unit to a place without any object that may block the beam.
Frost, snow or heavy rain cause false alarm
Optical alignment not optimized See "5-1 OPTICAL ALIGNMENT" and make realignment.
Alarm activated even if the light is not
blocked
Object blocking the beam between transmitter and receiver
See "5-2 BEAM INTERRUPTION TIME"and set an appropriate interruption time
Vehicle or plant blocking the beam between transmitter
and receiver
Remove any object blocking the beam
Surface of transmitter/receiver cover soiled
Clean the cover (wipe the cover with a soft coth dampened with water or
diluted neutral detergent)
Inaccurate optical alignement See "5-1 OPTICAL ALIGNMENT" and make realignment.
Inappropriate location of installation Change the location
After above inspections, if there remains any problem, contact our dealer or us immediately.
Do not use pole
bracket supplied
with the unit
Cut only the
required parts
with cutter
Cut with cutter.
Knockout
Note
Pole side cover
When the pole side cover fix on
the pole bracket, make sure the
position of the screws.
Note
Fix the pole side cover on
the pole bracket by using
the screws (8 pieces).
Pole side cover lock screw (The
same applies to the opposite side.)
After mounting the
units base, align
the optical axis and
check for the opera-
tion, then close the
cover. (See “3.
INSTALLATION”)
4. Mounting of the
unit base
Cut the perforation
with a cutter
Do not use pole bracket
supplied with the unit
Note
Fix the unit base body mounting-
plate and the pole bracket for the
option supplied with the pole side
cover by using the supplied screws.
Unit Base
Optional
pole bracket
(for PSC-3)
Mounting plate
lock screws
(for main unit)
Pole lock
screws
(for main unit)
25%