Datasheet
DS.MRI50A.ENG.30.03.23.BN
Mechancal Specfcatons
Techncal Specfcatons
Type of measurement
Resolution
Output channels
Output type
Power supply
Power consumption (without load)
Electrical connections
Max. permissible shaft loading radial
axial
Max. displacement speed
Rod diameter
Rod material
Case diameter
Case material
Protection level
Operating temperature
Storage temperature
Magnetic incremental non-contact
4 - 1024 ppr.
Push-Pull, TTL, Linedriver or Highlinedriver
8-24 VDC (standard) or 5 VDC (optional)
< 40 mA (24 VDC)
2,5 meter cable (standard)
100 N
60 N
3500 rpm
Stainless steel
Aluminium and painted steel
Ø50 mm
IP 54
-20°C ... +80°C
-30°C ... +90°C
Ø6 - 8 - 10 mm
The above technical datas are for information only. OPKON has the right for changing without any notifications.
Ordering Procedure
MRI 50A
Magnetc Incremental Encoder
INCREMENTAL
Push - Pull Cable Output
+V
0V
GND
: Brown
: White
: Shield
Ch A
Ch B
Ch Z
: Yellow
: Green
: Gray
TTL - HLD - Lnedrver Cable Output
+V
0V
GND
: Brown
: White
: Shield
Ch A
Ch B
Ch Z
: Yellow
: Green
: Gray
Ch A inv.
Ch B inv.
Ch Z inv.
: Blue
: Red
: Pink
• 50 mm case dameter
• Magnetc ncremental encoder
• Pulse optons:
4 - 8 - 16 - 20 - 25 - 32 - 40 - 50 - 66 - 80 - 100 - 125 -128 - 160
200 - 250 - 256 - 400 - 500 - 512 - 800 - 1000 - 1024 ppr.
• IP 54 protecton level
Model
MRI
MRI
Case diameter Case type
50
50 mm
A
A : Clamping flange
AW: Watertight
Rod diameter Output type
R8
R6
R8
: 6mm
: 8mm
R10
: 10mm
HLD
Resolution Output signal Power supply
Z V3
V1
V2
: 5V DC
: 8 - 24V DC
Connector / Cable
2M5
Cable output
R
R : Radial
A : Axial
500
TT
LD
LTP
HLD
: TTL
: Linedriver
: Push-Pull
: High Linedriver
4 - 1024 ppr. 2M5
5M
8M
10M
: 2,5 meter cable
: 5 meter cable
: 8 meter cable
: 10 meter cable
Z
B
: A, B, Z
: A, B
ZZ : AA, BB, ZZ
- - - -
A, B, Z or A,A, B,B, Z,Z
50
30
11
16 6 39
81
C
Rod Type / Axal
120º
3xM3
Ø40
D
R
(rod)
MRI 50A
C
Ø6 mm 5,50 mm
7,30 mm
9,00 mm
Ø8 mm
Ø10 mm
D
Ø40
M3x3
50
30 C
11
16 39
61
Rod type / Radal