Datasheet

DS.DMSW.CANBUS.ENG.12.05.23.AN
Ordering Procedure
Cursor
Connection
Above given technical data are only for information purpose. OPKON has right to change product specifications without notice.
2 / 2
G02
31,7
28
25
M5
28
22
7
18°
40
15,5
42
Connecting brackets
BR02
BR01
BR02
Model Measurement stroke Protocol
DMSW
100 - 5000 mm
DMSW
150 COB
COB:
CANbus
Cursor
Baud rade
6BR
Termination
1S0
1S0: off
1S1: on
Dead zone
0BR:10 kbit/s
1BR:20 kbit/s
2BR:50 kbit/s
3BR:100 kbit/s
4BR:125 kbit/s
5BR:250 kbit/s
6BR:500 kbit/s
7BR:800 kbit/s
8BR:1 Mbit
103/47
2000 mm
103/47
> 2000-3000 mm
145/47
> 3000-4000 mm
175/47
> 4000-5000 mm
215/47
1G02
1G02: 1
cursor
2G02: 2
cursors
1:
cursor
2:
cursors
M12 Male Connector
54
13
12
20
DMSW
M12 Female
in/out
CANH 2
4 CANL
3 0V
+24 VDC 5
NC 1
CANH 2
4 CANL
3 0V
+24 VDC 5
NC 1
M12 Female
in/out
Error(red)Status(green)