Datasheet

Measuring range 100 - 5000 mm
PROFIBUS protocol
24 VDC power supply
Measurement stroke
Resolution
Repeatability
Power supply
Output
Displacement speed
Max. comsumption
100 µm
PROFIBUS
100 - 5000 mm
max. < 5 m/s
<100 mA (depending on stroke length)
Up to ±0,05% full scale (min.100 µm)
24 VDC ±10%
Reverse polarity protection
Overvoltage protection
Up to -30 VDC
Up to +30 VDC
Update time 1 ms (at 1Mbit/s)
Interface RS422 / RS485
Data-length
Baud rate max. 12 Mbit / sec. (auto dedection)
25µm (100mm-400mm), 50µm (450mm-3000mm), 100µm (3001mm-5000mm)
16 bit
Red led : Error, Stop mode
1 / 2
L
37,5
15
45
11
59,5
10
M5x20
50
47
103
40
33
ML
25
48
66
65
Linedriver
Protokol PROFIBUS V0 / V1 / V2
Communication
Galvanic isolated
PROFIBUS
Protection level IP 65
20
Sensor adress (Node ID)
Operating temperature
Storage temperature
Mechanical Specifications
Technical Specifications
DMSW (mm)
ML
(Measuring Length)
L
(Total Length)
198
348
298
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1000 1100 1200 1300 1400 1500 1750 2000 2250 2500 3000 4000 5000
100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1000 1100 1200 1300 1400 1500 1750 2000 2250 2500 3000 4000 5000
248
398
348
498
448
598
548
698
648
798
748
898
848
998
948 1098 1198 1298 1398 1498 1598 1848 2211 2461 2711 3211 4211 5211
398 448 548 648 748498 598 698 798 848 898 948 998 1048 1098 1148 1248 1348 1448 1548 1648 1748 1998 2272 2522 2772 3302 4342 5342
103/47 mm
Dead Zone Calculation
MS
(Installation Length)
-10°C ... +70°C
-30°C ... +90°C
DS.DMSW.PROFIBUS.ENG.12.05.23.AN
Linearity
Diagnostic LEDs Green led: Power on, BUS communication active
Above given technical data are only for information purpose. OPKON has right to change product specifications with notice.
DMSW
Non-Contact
Magnetostrictive Position Sensor

Summary of content (2 pages)