Datasheet

2 / 2
Ordering Procedure
Cursor
Connection
M12 Male Connector
R02
22,5
24
4,3
7,5
13,5
33
R03
60°
33
13,5
4,3
115°
3
21
6
8
R01
25
12,5
18,5
3,2
R04
48
60
30
4,5
90°
15
8
8
54
13
12
20
DS.DMST.PROFIBUS.ENG.12.05.23.AN
Model
Rod & Thread
Measurement stroke Protocol
DMST 100 - 5000 mm
DMST
150
Cursor
37/53
Dead zone
E12
E10 : Ø10 , M18x1,5
E12 : Ø12 , M18x1,5
U10 : Ø10 , 3/4’’-16 UNF
U12 : Ø12 , 3/4’’-16 UNF
EO10 : Ø10 , M24x1,5
EO12 : Ø12 , M24x1,5
EA10 : Ø10 , M24x1,5
EA12 : Ø12 , M24x1,5
EB10 : Ø10 , M30x2
EB12 : Ø12 , M30x2
1R01: 25 mm
1R02: 33 mm
1R03: 33 mm
1R04: 60 mm
1R01: 1 cursor
2R01: 2 cursors
1R02
2000 mm
30/53
37/53
47/53
57/53
67/53
77/53
30/60
51/63
> 2000-3000 mm
130/53
> 3000-5000 mm
150/53
PFB
PFB:
Profibus
Node - ID
20
1 - 127
Termination
1S0
S
S: O-ring
F: Flat
Sealing surface
Termination:
1S0: off
1S1: on
DMST
M12 FemaleM8 Male
in/out
PB_B 2
4 PB_A
3 Bus_GND
Shield 5
Bus +5VDC 1
Error(red)Status(green)
power
NC 2
24 VDC 1
3 NC
4 0V
Above given technical data are only for information purpose. OPKON has right to change product specifications with notice.