2.6.1 Turn-On Procedure
Verify all RF connectors are tightened and cables and antennas are secured.
Connect AC/DC Adaptor on the repeater’s DC IN connector. The Power indicator
LED should be green. Make sure that no other LED is illuminated. If any other
LED is lit, consult the trouble shooting page of this manual, or “2.6.2 Antenna
Isolation and Alignment” section.
2.6.2 Antenna Isolation and Alignment
USHR-800NI is equipped with an over drive protection circuit. If the output power
level of reverse path(=Up Link) exceeds prescribed limit, then reverse path is
disconnected and the FAIL LED (RED) is on. Bi-Directional amplifier
automatically checks output power level every 1 minute of a 5 minute cycle when
reverse path has over power . If reverse path still exceeds level then shut down
mode continues for another 10 minutes. After 10 minutes, reverse path is switched
on again and it checks output power level again. (Repeats the process)
A. Antenna Alignment
If you are triggering the overdrive alarms at any point, try to increase the isolation
between the antennas by relocating them. The indoor antenna should be placed
physically as far away from the outdoor antenna as practical. If the geometry of the
intended coverage area allows it, you should also try the indoor antenna in such
way that interference between the antennas is at the minimum. If you are using
directional antennas, try to find a location for the indoor antenna where it can cover
the needed area and oriented back to back with respect to the outdoor antenna.
2.7 Connectors
Figure 2-7 shows the connectors and Table 2-7 provides a description of each
connector on the USHR-800NI unit
<Table 2-7: USHR-800NI Connectors>
Label Description
DC IN
Connect AC/DC Adaptor for supplying DC power to the
unit
TO BASE
SMA-type female connector transmits base station RF,
receives mobile RF, and connects to the outdoor antenna
TO MOBILE
SMA-type female connector transmits mobile RF,
receives base station RF, and connects to the indoor
antenna