- 1.2 . Features 1.2.1. Summary This device may be installed on residential area, office, warehouse etc. . Following is advantage of using in-building repeater system. This is RF type amplifier for 700 MHz LTE of Band 12 and Band 13 signal enhancement. (Please see page 13 for Operating Frequency in details) 1.2.2 . Features
- 1.2.3. Function
- 1.2.3. Function
- 슬라이드 번호 7
- 3. Installation3.1. Installation diagram
- 슬라이드 번호 9
- 슬라이드 번호 10
- 슬라이드 번호 11
- 슬라이드 번호 12
- 슬라이드 번호 13
- 슬라이드 번호 14

Page 10
5. Specification
5.1. Electrical Specification
Item Specifications Note
Frequency Range
Down Link 728 ~ 746 MHz
BAND12
Up Link 698 ~ 716 MHz
Down Link 746 ~ 757 MHz
BAND13
Up Link 776 ~ 787 MHz
Modulation Type GSM. EDGE, CDMA, EVDO, HSPA, LTE
Input Power limit
Down Link -45dBm max
BAND12
Up Link -13dBm max
Down Link -45dBm max
BAND13
Up Link -13dBm max
Output Power
Down Link +2dBm @ booster output port LTE DL 5MHz 25RB
Up Link +22dBm @ booster output port LTE UL 5MHz 25RB
Down Link +2dBm @ booster output port LTE DL 5MHz 25RB
Up Link +22dBm @ booster output port LTE UL 5MHz 25RB
Gain
Down Link 47dB ~ 61dB (±1.0dB)
BAND12
Up Link 35dB ~ 60dB (±1.0dB)
Down Link 47dB ~ 61dB (±1.0dB)
BAND13
Up Link 35dB ~ 60dB (±1.0dB)
Ripple
Down / Up Link < 4dB BAND12
Down / Up Link < 4dB BAND13
Noise Figure
Down / Up Link < 6.0dB / < 6.0dB BAND12 Max Gain
Down / Up Link < 6.0dB / < 6.0dB BAND13 Max Gain
Noise Power Limit
Down Link < -70dBm/MHz On shutdown
Up Link < -70dBm/MHz On shutdown & sleep mode
Down / Up Link FCC BAND12
Down / Up Link FCC BAND13
Propagation Delay < 3us
VSWR ≤ 1.8 : 1
ALC Setting Level
D
own Link(Upper Value) +2dBm±1.0dB
- ALC, SD, OSC functional opera
tion is completely separate BAN
D12 and BAND13.
Window Size(Lower Offset) 0 ~ 10dB
Up Link (Upper Value) +22dBm±1.0dB
Window Size(Lower Offset) 0 ~ 10dB
ALC Range
Down Link ≤ 14dB
Up Link ≤ 25dB
Uplink Gain limit
DL starting input level
for Uplink Gain
Interlocking
-68 dBm
Shutdown Level
Down Link > -45dBm/Total
Up Link > -13dBm/Total
OSC Level
Down Link DL detects OSC under 1 sec.
Up Link UL detects OSC under 0.3 sec.
Uplink In-activity Up link On@ > -90dBm, OFF@ < -92dBm - No uplink signal for 5 minutes