FR902DP

16
WARNING! TURN ALL POWER OFF TO THE
DISPENSER AND PUMP AT THE BREAKER
PRIOR TO PERFORMING ANY SERVICE.
Release any pressure in the piping, hoses, and
nozzle prior to performing any service. Failure to
comply with these warnings can result in
explosion, fire, bodily injury, and possibly death.
For accurate measurement and to prevent dispenser damage, dispenser and piping must always
be filled with liquid and be free of air. Where applicable, the meter portion of your dispenser
should be calibrated per instructions in the meter manual prior to its use.
1. Reset register to “0”.
2. Remove nozzle from holder and turn the power on by lifting the switch handle.
3. Dispenser is ready for use. Insert nozzle into container to be filled and start flow of liquid. Do
not exceed 50 PSI of line pressure. When desired amount of liquid has been dispensed, stop
the flow at the nozzle. Turn the power off by pushing the switch handle down. Return the
nozzle to its holder.
Assembly and Disassembly
Model
Gasoline
Diesel
Bio-Diesel
Kerosene
Lube Oil (60w and less)
FR102PH
FR302DP
FR902DP
FR910PM
Material
FR102PH
FR302DP
FR902DP
FR910PM
Aluminum
Stainless Steel
Fluorocarbon
Buna-N
Cast Iron
Carbon
Nickle Plated Aluminum
Acetal
Polyester
Steel
Cabinets consist of three major pieces:
1) Base / back plate (internal
equipment installed on it)
2) Cabinet walls that enclose the
internal components
3) Cabinet top
Fluid Compatibility
Wetted Parts
1
2
3