User's Manual

Part Number 110449
Revision Date: January 18, 2011
Read All Instructions! Failure To Follow All Instructions Listed Below
May Result In An Unsafe Or Dangerous Condition.
Before Lifting Operation
o Ensure that all operators are qualified to operate the lifting Magnet and are familiar with ASME B30.20 lifting standards.
o DO NOT use the Magswitch Lifter product if the unit or Remote is damaged or is not working properly. Severe injury can occur if this
device is not used properly and safely.
o Always inspect the lifting device to ensure that it is in good working order. Maintain inspection and records of same as per ASME B30.20.
o Never operate an unsafe or ‘out-of-service’ tagged Magnet, or one with missing parts or labels.
o Never operate a lifting Magnet when Capacity, Weight or Safety Markings are missing, damaged or obscured.
o DO NOT attempt to disassemble the Magswitch Magnet; there are no user serviceable parts inside the device.
o All Magswitch products are designed for normal worksite/jobsite conditions, do not use underwater or in a hazardous environment unless
specifically designed for that purpose.
o DO NOT attempt to alter the device in any way. This will void the warranty and may result in an unsafe or dangerous condition.
o Never exceed the rated load of the Magswitch magnet. This may result in an unsafe or dangerous condition. See DeRating factors for
more details of load rating factors. Magnet performance will vary based on type, thickness and length of steel you are lifting. We
recommend when lifting Sheets over 8’, use 2 or more lifts on a spreader bar to prevent sheet flexing, sagging or peel off.
o Ensure all Electronics are working properly and battery is charged. The green light on the power button of the unit will blink if the
battery is low. If the Battery power is depleted, the light will not come one. Important: the magnet will stay in the position it was in
before the battery drained On or OFF, it will NOT shut off if power lost.
o Ensure that the Magnet is stored in the “off” position when not in contact with metals.
o Never turn the Magnet ‘ON’ unless it is in contact with Ferro-Magnetic metal. The magnets can be left ON or Off indefinitely without
harm, however when they are in the ON position, and near ferromagnetic materials, there will be a powerful magnetic attraction.
Important Safety Information
o Always be aware of where the remote is while handling the unit. The unit can be actuated from the remote or on the Lifter.
o Never turn the Magnet ‘ON’ unless it is in contact with Ferro-Magnetic metal. The magnets can be left ON or Off indefinitely without
harm, however when they are in the ON position, and near ferromagnetic materials, there will be a powerful magnetic attraction.
o Always test the connection before attempting to use the Magnet to ensure that it is capable of lifting the material securely.
o Always perform a Test Lift of no more than 2-3 inches (10 cm) to ensure that the bond is sufficient to lift the load and that the load is
not flexing.
o Always ensure that when stacked sheets are present, that only one sheet is being lifted at a time.
o When lifting, never exceed 33% of the Breakaway force of the Magnet. All Magswitch lifting magnets are rated at 1/3 of their
Breakaway force for safety. Please refer to the label on the individual magnet for the safe working load.
o Always ensure that the lifting hoist is capable of lifting the combined weight of the load plus the Magnet.
o Operator shall immediately stop using the lifting Magnet if any improper performance or conditions exist during the lift.
o This Magnetic lifter is designed for straight, flat horizontal lifting, never allow a lifted object to alter is plane from horizontal.
o Avoid sudden jerking or Shock force as this may cause the Magnet to lose its hold.
o Use Caution to ensure that it is safe to release the Magnet, that people are clear of Danger if the load should fall or become dangerous.
o DO NOT expose the Magswitch Magnets to temperatures above 176 deg Fahrenheit (80 Celsius). High temperatures will permanently
degrade the Magnet’s effectiveness and may result in an unsafe condition.
o DO NOT Operate the Magnet at temperatures greater than 120 deg Fahrenheit (49 Celsius).
o Never use a Magswitch lifter for OVERHEAD LIFTING.
o Never stand under load being lifted or place any part of your body under the load.
o DO NOT lift a load higher than necessary.