User's Manual

Toll Free: 1-888-582-0822 Fax: 231-582-2704
MAG-MATE GROUP
2
After The Lift Operation & Safety Measures
ALWAYS check Lifting Magnet to ensure that no damage occurred and that is still
complies with all requirements above.
ALWAYS wipe off any debris or contaminants that became attracted to the Magnet
that would prevent a safe lift in the future.
ALWAYS notify the designated person in your company of any problems or concerns
regarding the operation of the Magnet.
ALWAYS store the Magnet in a safe location and in the “OFF” position to ensure that
no damage can occur or accidental contact with metal be made. Ensure
that the storage area is free of humidity, debris, shavings etc.
ALWAYS le any burrs that would interfere with full contact. For safe operation,
the bottom surface of the Magnet must always be Flat and Smooth. If
necessary, it is possible to sand the Magnet face smooth using 400 grit
sandpaper and a fl at surface.
Important General Safety Measures & Information Continued
DO NOT allow the lifted object to alter its plane from horizontal. Never lift load at an
angle in excess of 5° from horizontal
DO NOT operate or expose this lifting device at temperatures greater than 120
degrees Fahrenheit (49°C).
DO NOT use a Magnetic lifter for OVERHEAD LIFTING.
DO NOT carry people or allow people to ride on materials being lifted.
DO NOT lift a load higher than necessary or leave a lifted load unattended.
DO NOT disengage the lift before fi rmly setting down the load on the fl oor or support
& making sure the load is steadied.
DO NOT weld in close proximity to the magnet or use the magnet as a part of the
ground circuit during a welding operation
DO NOT place the magnet directly onto a grounded fl oor. Use a non-conductive
spacer
Operating Instructions
ACTUATING THE MAGNET “ON”
Actuation of the unit with the Remote Control
1. Ensure magnet is positioned correctly in full contact with load
2. Ensure power is on (Power button light is active)
3. Press green “ON” button on remote once to actuate magnet
4. LOOK for amber lights to become active on indicator light dome
5. LISTEN for motor sound
6. TEST small lift before moving load
Actuation of the unit without the Remote Control
1. Ensure magnet is positioned correctly in full contact with target
2. Ensure power is on (Power button light is active)
3. Press green “ON” button on magnet housing once to actuate magnet
4. LOOK for amber lights to become active on indicator light dome
5. LISTEN for motor sound
6. TEST small lift before moving load
ACTUATING THE MAGNET “OFF”
Actuation of the unit with the Remote Control
1. Ensure target load is settled, lift ring is in lowest position and cable is slightly slack.
2. Press the release sequence on the remote control once: OFF > ON > OFF
3. LOOK for amber lights to begin fl ashing on indicator light dome
4. WAIT Three seconds
5. LISTEN for motor sound
6. LOOK for amber lights to become inactive on indicator light dome
7. TEST small lift to ensure target is fully released
Actuation of the unit without the Remote Control
1. Ensure target load is settled, lift ring is in lowest position and cable is slightly slack.
2. Press the release sequence on the magnet housing once: OFF > ON > OFF
3. LOOK for amber lights to begin fl ashing on indicator light dome
4. WAIT Three seconds
5. LISTEN for motor sound
6. LOOK for amber lights to become inactive on indicator light dome
7. TEST small lift to ensure target is fully released
Troubleshooting Instructions
BEFORE ATTEMPTING ANY TROUBLESHOOTING, VERIFY LOAD IS SECURED IN A SAFE CONDITION AND READ MANUAL THOROUGHLY.
If this lifter malfunctions and cannot deactivate, immediately cease operations with this magnet assembly. Follow the steps outlined below to deactivate the magnet. If
problems persist, please call 888-582-0822 for help with further troubleshooting or servicing.
Troubleshooting Deactivation (Perform before using Manual Release)
1. Ensure target load is settled, lift ring is in lowest position and cable is slightly slack.
2. If using remotely, attempt to deactivate device with buttons on the lifter
3. Replace remote batteries if needed
4. Turn power to unit off, wait 10 seconds, turn power to unit on
5. Check that power button is solid green, replace battery if necessary
Manual Release Operation (Use only when Powered Actuation fails)
1. Ensure target load is settled, lift ring is in lowest position and cable is slightly slack.
2. Remove the Manual Actuation Lever by pulling up vertically on the black knurled
cylinder next to the indicator light dome
3. Screw Manual Actuation Lever into Manual Actuation Lever Attachment Point
4. Ensure Manual Actuation Lever is completely screwed in
5. Depress the Override Button (silver) with one hand and rotate the lever 180 degrees
counter clockwise with the other.
6. The magnet should now be deactivated.
7. Release the Override Button
8. Unscrew the lever and replace in the storage sleeve