PARAMETER CHECKING AND ADUSTMENT
Parameter list
Some parameters can be checked and adjusted by the controller. Below is the parameter list.
Parameter
No.
Description Range Default Remarks
0Tankwatersettingtemp.10~70°C50°CAdjustable
1
Inlet/Outlet water temp
difference
2~15°C 5°C Adjustable
2E-heaterofftankwatertemp10~85°C55°CAdjustable
3E-heaterdelaytime 0~90min6t*5min
4Weekdisinfectiontemperature50~70°C70°CAdjustable
5Hightempdisinfectiontime0~90min30minAdjustable
6Defrostingperiod 30~90min45minAdjustable
7Defrostingentrycoiltemp.-30~0°C-7°CAdjustable
8Defrostingexitcoiltemp.2~30°C13°CAdjustable
9Maxdefrostingcycleperiod1~12min8minAdjustable
10
Electronic expansion valve
adjustment
0/1 1
Adjustable (0-manual,
1-auto)
11 Target over-heat degree -9 ~ 9°C 5°C Adjustable
12
Steps of manually adjusting the
electronic expansion valve
10 ~ 50 step 35 step Adjustable
13
Disinfection start up time
adjusting
0~23 23 Adjustable(hour)
AInletwatertemp. -9~99°C
Actual testing value. Error code
PP1 will be shown in case of a
malfunction
BOutletwatertemp. -9~99°C
Actual testing value. Error code
PP2 will be shown in case of a
malfunction
CEvaporatorcoiltemp. -9~99°C
Actual testing value. Error code
PP3 will be shown in case of a
malfunction
DReturngastemp. -9~99°C
Actual testing value. Error code
PP4 will be shown in case of a
malfunction
EAmbienttemp. -9~99°C
Actual testing value. Error code
PP5 will be shown in case of a
malfunction
FElectronicexpansionvalvestep10~47stepN*10step