User's Manual
Vst/Pst Controller Ver. A1.00
Installation Requirements
P/N 1100035 page 3-4
3.1 PST Antenna Wiring.
The PST antenna in the window panel is wired to the VST/PST Controller via BNC
connector near the window panel. Wiring should be performed by qualified technetium
only.
The PST antenna in the window panel has a 23” coax cable terminated with a BNC
connector.
Connect this cable to a 22 foot long RG174 coax cable routed through protected
conduit and connected to the VST/PST Controller MCI terminal strip (refer to Figure 3-
2: VST/PST Signal Wiring).
THE ANTENNA CABLES MUST NOT BE CUT! They must be used in the length
provided.
Note:
After connecting the PST antenna cable to the cable from the VST/PST controller, wrap
3M Scotch-Seal 2229 Mastic Tape over the BNC connectors to seal them against
moisture
3.2
Supervisor
Antenna wiring
The Supervisor antenna should be placed near the payment window terminal printer. It
is intended as interface between the Supervisor card and the system.
Secure antenna in place with mounting screws.
Make sure the antenna is not mounted over or placed near a metallic surface!
The antenna is supplied with a 23 feet 11 inch RG174 coax cable. The coax cable
should be routed through protected conduit and connected to the VST/PST Controller
MCI terminal strip (Refer to Figure 3-2: VST/PST Signal Wiring).
THE ANTENNA CABLE MUST NOT BE CUT! It must be used in the length
provided.
3.3 VST Antenna wiring
Use RG58 coax cable. The VST antenna is wired to the VST/PST controller. Both VST
antenna and VST/PST Controller have SMA connectors. Wiring should be performed
by qualified technetium only.