3.2 Antenna
The SCIBA-2 is supplied with standard antennas with which the system was EMC certified.
The use of other antennas requires re-testing and certification.
Enclosure ABS Plastic
Protection IP__
The antenna is provided with two cable tails
1. Six-wire cable tail with Molex 6 pole connector connected to the antenna’s three
LEDs and buzzer
2. Coax cable tail with the MCX connector which is connected to the antenna’s RF
coil.
Important!
Use coax cable in length provided.
Do not shorten or lengthen coax cable.
3.3 Power Supply
Power supply voltage should be in the range of 7.0 to 15VDC.
If the power supply may provide current more than 5A a fuse of 4.5A should be used, if
the maximum power supply current less than 5A there are no special requirements.
Standard power adapter, mains/(9 to 12 V DC) is recommended for use:
9VDC or 12VDC 500mA
.