Datasheet
TIP3055 TIP2955
http://onsemi.com
2
ELECTRICAL CHARACTERISTICS (T
C
= 25C unless otherwise noted)
Characteristic Symbol Min Max Unit
OFF CHARACTERISTICS
Collector–Emitter Sustaining Voltage (1)
(I
C
= 30 mAdc, I
B
= 0)
V
CEO(sus)
60 — Vdc
Collector Cutoff Current
(V
CE
= 70 Vdc, R
BE
= 100 Ohms)
I
CER
— 1.0 mAdc
Collector Cutoff Current
(V
CE
= 30 Vdc, I
B
= 0)
I
CEO
— 0.7 mAdc
Collector Cutoff Current
(V
CE
= 100 Vdc, V
BE(off)
= 1.5 Vdc)
I
CEV
— 5.0 mAdc
Emitter Cutoff Current
(V
BE
= 7.0 Vdc, I
C
= 0)
I
EBO
— 5.0 mAdc
ON CHARACTERISTICS (1)
DC Current Gain
(I
C
= 4.0 Adc, V
CE
= 4.0 Vdc)
(I
C
= 10 Adc, V
CE
= 4.0 Vdc)
h
FE
20
5.0
70
—
—
Collector–Emitter Saturation Voltage
(I
C
= 4.0 Adc, I
B
= 400 mAdc)
(I
C
= 10 Adc, I
B
= 3.3 Adc)
V
CE(sat)
—
—
1.1
3.0
Vdc
Base–Emitter On Voltage
(I
C
= 4.0 Adc, V
CE
= 4.0 Vdc)
V
BE(on)
— 1.8 Vdc
SECOND BREAKDOWN
Second Breakdown Collector Current with Base Forward Biased
(V
CE
= 30 Vdc, t = 1.0 s; Nonrepetitive)
I
s/b
3.0 — Adc
DYNAMIC CHARACTERISTICS
Current Gain — Bandwidth Product
(I
C
= 0.5 Adc, V
CE
= 10 Vdc, f = 1.0 MHz)
f
T
2.5 — MHz
Small–Signal Current Gain
(V
CE
= 4.0 Vdc, I
C
= 1.0 Adc, f = 1.0 kHz)
h
fe
15 — kHz
(1) Pulse Test: Pulse Width = 300 µs, Duty Cycle 2.0%.
NOTE: For additional design curves, refer to electrical characteristics curves of 2N3055.
I
C
, COLLECTOR CURRENT (AMPS)
10
5.0
0.1
0.3
2.0
3.0
Figure 2. Maximum Rated Forward Bias
Safe Operating Area
V
CE
, COLLECTOR-EMITTER VOLTAGE (VOLTS)
1.0 2.0 4.0 6.0 10 20
0.2
0.5
1.0
20
30
50
100
40 60
SECONDARY BREAKDOWN LIMIT
BONDING WIRE LIMIT
THERMAL LIMIT @ T
C
= 25°C
T
J
= 150°C
300 µs
1.0ms
10ms
dc
There are two limitations on the power handling ability of
a transistor: average junction temperature and second
breakdown. Safe operating area curves indicate I
C
– V
CE
limits of the transistor that must be observed for reliable
operation; i.e., the transistor must not be subjected to greater
dissipation than the curves indicate.
The data of Figure 2 is based on T
C
= 25C; T
J(pk)
is
variable depending on power level. Second breakdown
pulse limits are valid for duty cycles to 10% but must be