FINAL PRODUCT/PROCESS CHANGE NOTIFICATION # 16827
Issue Date: 09-Mar-2012 Rev. 06-Jan-2010 Page 2 of 5
RELIABILITY DATA SUMMARY:
Package: TO-247
Qual Vehicles: MJW21195G, MJW21196G, TIP32CG, TIP36CG, BU323ZG
MJW21195G
Test: Conditions: Interval: Results
Autoclave+PC Ta=121C RH=100% ~15 psig 96 hrs 0/77
H3TRB+PC Ta=85C RH=85% 1008 hrs 0/77
bias=80% rated V or100V Max
IOL+PC Ta=25C, Delta TJ = 100 C, 8572 cyc 0/77
Ton/off = 3.5 min.
TC+PC Ta= -65 C to 150 C 1000 cyc 0/77
RSH Ta=260C, 10 sec dwell 0/30
MJW21196G
Test: Conditions: Interval: Results
Autoclave+PC Ta=121C RH=100% ~15 psig 96 hrs 0/77
H3TRB+PC Ta=85C RH=85% 1008 hrs 0/77
bias=80% rated V or100V Max
IOL+PC Ta=25C, Delta TJ = 100 C, 8572 cyc 0/77
Ton/off = 3.5 min.
TC+PC Ta= -65 C to 150 C 1000 cyc 0/77
RSH Ta=260C, 10 sec dwell 0/30
TIP32CG
Test: Conditions: Interval: Results
Autoclave+PC Ta=121C RH=100% ~15 psig 96 hrs 0/77
H3TRB+PC Ta=85C RH=85% 1008 hrs 0/77
bias=80% rated V or100V Max
TIP36CG
Test: Conditions: Interval: Results
Autoclave+PC Ta=121C RH=100% ~15 psig 96 hrs 0/77
TC+PC Ta= -65 C to 150 C 1000 cyc 0/77
BU323ZG
Test: Conditions: Interval: Results
Autoclave+PC Ta=121C RH=100% ~15 psig 96 hrs 0/77
H3TRB+PC Ta=85C RH=85% 1008 hrs 0/77
bias=80% rated V or100V Max