Datasheet
MUR805, MUR810, MUR815, MUR820, MUR840, MUR860
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol
MUR
Unit
805 810 815 820 840 860
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
50 100 150 200 400 600 V
Average Rectified Forward Current
Total Device, (Rated V
R
), T
C
= 150°C
I
F(AV)
8.0 A
Peak Repetitive Forward Current
(Rated V
R
, Square Wave, 20 kHz), T
C
= 150°C
I
FM
16 A
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions halfwave, single phase, 60 Hz)
I
FSM
100 A
Operating Junction Temperature and Storage Temperature Range T
J
, T
stg
−65 to +175 °C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
THERMAL CHARACTERISTICS
Rating Symbol
MUR
Unit
805 810 815 820 840 860
Maximum Thermal Resistance, Junction−to−Case
R
q
JC
3.0 2.0 °C/W
ELECTRICAL CHARACTERISTICS
Rating Symbol
MUR
Unit
805 810 815 820 840 860
Maximum Instantaneous Forward Voltage (Note 1)
(i
F
= 8.0 A, T
C
= 150°C)
(i
F
= 8.0 A, T
C
= 25°C)
v
F
0.895
0.975
1.00
1.30
1.20
1.50
V
Maximum Instantaneous Reverse Current (Note 1)
(Rated DC Voltage, T
J
= 150°C)
(Rated DC Voltage, T
J
= 25°C)
i
R
250
5.0
500
10
mA
Maximum Reverse Recovery Time
(I
F
= 1.0 A, di/dt = 50 A/ms)
(I
F
= 0.5 A, i
R
= 1.0 A, I
REC
= 0.25 A)
t
rr
35
25
60
50
ns
1. Pulse Test: Pulse Width = 300 ms, Duty Cycle ≤ 2.0%.
