Datasheet

MUR8100E, MUR880E
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol Value Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage MUR880E
MUR8100E
V
RRM
V
RWM
V
R
800
1000
V
Average Rectified Forward Current
(Rated V
R
, T
C
= 150°C) Total Device
I
F(AV)
8.0 A
Peak Repetitive Forward Current
(Rated V
R
, Square Wave, 20 kHz, T
C
= 150°C)
I
FM
16 A
Non−Repetitive Peak Surge Current
(Surge Applied at Rated Load Conditions Halfwave, Single Phase, 60 Hz)
I
FSM
100 A
Operating Junction and Storage Temperature Range T
J
, T
stg
−65 to +175 °C
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
THERMAL CHARACTERISTICS
Characteristic Symbol Value Unit
Maximum Thermal Resistance, Junction−to−Case
R
q
JC
2.0 °C/W
ELECTRICAL CHARACTERISTICS
Characteristic Symbol Value Unit
Maximum Instantaneous Forward Voltage (Note 1)
(i
F
= 8.0 A, T
C
= 150°C)
(i
F
= 8.0 A, T
C
= 25°C)
v
F
1.5
1.8
V
Maximum Instantaneous Reverse Current (Note 1)
(Rated DC Voltage, T
C
= 100°C)
(Rated DC Voltage, T
C
= 25°C)
i
R
500
25
mA
Maximum Reverse Recovery Time
(I
F
= 1.0 A, di/dt = 50 A/ms)
(I
F
= 0.5 A, i
R
= 1.0 A, I
REC
= 0.25 A)
t
rr
100
75
ns
Controlled Avalanche Energy
(See Test Circuit in Figure 6)
W
AVAL
20 mJ
1. Pulse Test: Pulse Width = 300 ms, Duty Cycle 2.0%.