Data Sheet
MOCD207M, MOCD208M, MOCD211M, MOCD213M, MOCD217M
www.onsemi.com
2
Safety and Insulation Ratings
As per DIN EN/IEC 60747−5−5, this optocoupler is suitable for “safe electrical insulation” only within the safety limit data.
Compliance with the safety ratings shall be ensured by means of protective circuits.
Parameter Characteristics
Installation Classifications per DIN VDE 0110/1.89 Table 1, For Rated
Mains Voltage
< 150 V
RMS
I−IV
< 300 V
RMS
I−III
Climatic Classification 55/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
Comparative Tracking Index 175
Symbol Parameter Value Unit
V
PR
Input−to−Output Test Voltage, Method A, V
IORM
x 1.6 = V
PR
,
Type and Sample Test with t
m
= 10 s, Partial Discharge < 5 pC
904 V
peak
Input−to−Output Test Voltage, Method B, V
IORM
x 1.875 = V
PR
,
100% Production Test with t
m
= 1 s, Partial Discharge < 5 pC
1060 V
peak
V
IORM
Maximum Working Insulation Voltage 565 V
peak
V
IOTM
Highest Allowable Over−Voltage 4000 V
peak
External Creepage ≥4 mm
External Clearance ≥4 mm
DTI Distance Through Insulation (Insulation Thickness) ≥0.4 mm
T
S
Case Temperature (Note 1) 150 °C
I
S,INPUT
Input Current (Note 1) 200 mA
P
S,OUTPUT
Output Current (Note 1) 300 mW
R
IO
Insulation Resistance at T
S
, V
IO
= 500 V (Note 1) >10
9
W
1. Safety limit values – maximum values allowed in the event of a failure.