Datasheet
TL7757, TL7757Y
SUPPLY VOLTAGE SUPERVISOR
AND PRECISION VOLTAGE DETECTOR
SLVS041D – SEPTEMBER 1991 – REVISED AUGUST 1995
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature (unless otherwise noted)
†
Supply voltage range, V
CC
(see Note 1) –0.3 V to 20 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Offstate output voltage range (see Note 1) –0.3 V to 20 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current, I
O
30 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: C-suffix 0°C to 70°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I-suffix –40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M-suffix –55°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation See Dissipation Rating Tables. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values are with respect to network terminal ground.
DISSIPATION RATING TABLE 1 – FREE-AIR TEMPERATURE
PACKAGE
T
A
≤ 25°C DERATING DERATE
T
A
=70
°
C
T
A
=85
°
C
T
A
= 125
°
C
PACKAGE
A
POWER RATING FACTOR ABOVE
T
A
=
70°C
T
A
=
85°C
T
A
=
125°C
D 725 mW 5.8 mW/°C T
A
= 25°C 464 mW 377 mW 145 mW
LP 775 mW 6.2 mW/°CT
A
= 25°C 496 mW 403 mW 155 mW
PK 500 mW 4.0 mW/°C T
A
= 25°C 320 mW 260 mW —
DISSIPATION RATING TABLE 2 – CASE TEMPERATURE
PACKAGE
T
A
≤ 25°C DERATING DERATE
T
A
=70
°
C
T
A
=85
°
C
PACKAGE
A
POWER RATING FACTOR ABOVE
T
A
=
70°C
T
A
=
85°C
PK 3125 mW 25 mW/°C T
C
=110°C 2000 mW 1625 mW
recommended operating conditions
C-SUFFIX I-SUFFIX M-SUFFIX
UNIT
MIN MAX MIN MAX MIN MAX
UNIT
Supply voltage, V
CC
1 7 1 7 1 7 V
High-level output voltage, V
OH
15 15 15 V
Low-level output current, I
OL
20 20 20 mA
Operating free-air temperature, T
A
0 70 –40 85 –55 125 °C