Datasheet
MBRS3100T3G, NRVBS3100T3G
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol Value Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
100 V
Average Rectified Forward Current
(At Rated V
R
, T
L
= 100C)
I
F(AV)
3.0
A
Nonrepetitive Peak Surge Current
(Surge applied at rated load conditions halfwave, single phase, 60 Hz)
I
FSM
130
A
Operating Junction Temperature Range (Note 1) T
J
− 65 to +175 C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
1. The heat generated must be less than the thermal conductivity from Junction−to−Ambient: dP
D
/dT
J
< 1/R
q
JA
.
THERMAL CHARACTERISTICS
Characteristic Symbol Value Unit
Thermal Resistance, Junction−to−Lead
R
q
JL
11 C/W
ELECTRICAL CHARACTERISTICS
Characteristic Symbol Value Unit
Maximum Instantaneous Forward Voltage (Note 2)
(i
F
= 3.0 A, T
J
= 25C)
(i
F
= 6.0 A, T
J
= 25C)
(i
F
= 3.0 A, T
J
= 125C)
(i
F
= 6.0 A, T
J
= 125C)
V
F
0.79
0.90
0.62
0.70
V
Maximum Instantaneous Reverse Current (Note 2)
(Rated dc Voltage, T
J
= 25C)
(Rated dc Voltage, T
J
= 125C)
i
R
0.05
5.0
mA
2. Pulse Test: Pulse Width = 300 ms, Duty Cycle 2.0%.