Datasheet
MBR1035, MBR1045
http://onsemi.com
2
MAXIMUM RATINGS
Rating Symbol Value Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage MBR1035
MBR1045
V
RRM
V
RWM
V
R
35
45
V
Average Rectified Forward Current
(T
C
= 135°C, Per Device)
I
F(AV)
10
A
Peak Repetitive Forward Current,
(Square Wave, 20 kHz, T
C
= 135°C)
I
FRM
10 A
Non−Repetitive Peak Surge Current
(Surge Applied at Rated Load Conditions Halfwave, Single Phase, 60 Hz)
I
FSM
150 A
Peak Repetitive Reverse Surge Current (2.0 ms, 1.0 kHz)
I
RRM
1.0 A
Storage Temperature Range T
stg
−65 to +175 °C
Operating Junction Temperature (Note 1) T
J
−65 to +175 °C
Voltage Rate of Change
(Rated V
R
)
dv/dt
10,000
V/ms
Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit
values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied,
damage may occur and reliability may be affected.
1. The heat generated must be less than the thermal conductivity from Junction−to−Ambient: dP
D
/dT
J
< 1/R
q
JA
.
THERMAL CHARACTERISTICS
Characteristic Conditions Symbol Max Unit
Maximum Thermal Resistance, Junction−to−Case Min. Pad
R
q
JC
2.0
°C/W
Maximum Thermal Resistance, Junction−to−Ambient Min. Pad
R
q
JA
60
ELECTRICAL CHARACTERISTICS
Characteristic Symbol Min Typical Max Unit
Instantaneous Forward Voltage (Note 2)
(i
F
= 10 Amps, T
j
= 125°C)
(i
F
= 20 Amps, Tj = 125°C)
(i
F
= 20 Amps, Tj = 25°C)
v
F
−
−
−
0.55
0.67
0.78
0.57
0.72
0.84
V
Instantaneous Reverse Current (Note 2)
(Rated dc Voltage, Tj = 125°C)
(Rated dc Voltage, Tj = 25°C)
i
R
−
−
5.3
0.008
15
0.1
mA
2. Pulse Test: Pulse Width = 300 ms, Duty Cycle ≤ 2.0%.