Data Sheet
FODM30XX — 4-Pin Full Pitch Mini-Flat Package Random-Phase Triac Driver Output Optocouplers
Electrical Characteristics
T
A
= 25°C unless otherwise specified.
Individual Component Characteristics
Notes:
2. Test voltage must be applied within dv/dt rating.
3. This is static dv/dt. See Figure 1 for test circuit Commutating dv/dt is function of the load-driving thyristor(s) only.
Transfer Characteristics
Notes:
4. All devices are guaranteed to trigger at an I
F
value of less than or equal to the max I
FT
specification. For optimum
operation over temperature and lifetime of the device, the LED should be biased with an I
F
that is at least 50%
higher than the maximum I
FT
specification. The I
FT
should not exceed the absolute maximum rating of 60 mA.
Example: For FODM0353M, the minimum I
F
bias should be 5 mA x 150% = 7.5 mA
Isolation Characteristics
Symbol Parameter Test Conditions Device Min. Typ. Max. Unit
EMITTER
V
F
Input Forward Voltage I
F
= 10 mA All 1.20 1.50 V
I
R
Reverse Leakage Current V
R
= 3 V, T
A
= 25°C All 0.01 100 μA
DETECTOR
I
DRM
Peak Blocking Current Either
Direction
Rated V
DRM
, I
F
= 0
(2)
All 2 100 nA
dV/dt
Critical Rate of Rise of
Off-State Voltage
I
F
= 0 (Figure 8)
(3)
FODM3011,
FODM3012,
FODM3022,
FODM3023
10
V/μs
FODM3052,
FODM3053
1,000
Symbol Parameter Test Conditions Device Min. Typ. Max. Unit
I
T
LED Trigger Current
Main Terminal
Voltage = 3 V
(4)
FODM3011,
FODM3022,
FODM3052
10
mA
FODM3012,
FODM3023,
FODM3053
5
I
H
Holding Current, Either
Direction
All 450 µA
V
TM
Peak On-State Voltage Either
Direction
I
TM
= 100 mA peak All 2.2 3 V
Symbol Parameter Test Conditions Device Min. Typ. Max. Unit
V
ISO
Steady State Isolation
Voltage
1 Minute,
R.H. = 40% to 60%
All 3,750 VAC
RMS
www.onsemi.com
4