Data Sheet

© Semiconductor Components Industries, LLC, 2010 www.onsemi.com
FOD8316 Rev. 2 4
FOD8316 — 2.5 A Output Current, IGBT Drive Optocoupler with Desaturation Detection and Isolated Fault Sensing
Safety and Insulation Ratings
As per DIN EN/IEC 60747-5-5, this optocoupler is suitable for “safe electrical insulation” only within the safety limit
data. Compliance with the safety ratings must be ensured by means of protective circuits.
Symbol Parameter Min. Typ. Max. Unit
Installation Classifications per DIN VDE 0110/1.89 Table 1
Rated Mains Voltage < 150 V
RMS
I–IV
Rated Mains Voltage < 300 V
RMS
I–IV
Rated Mains Voltage < 450 V
RMS
I–IV
Rated Mains Voltage < 600 V
RMS
I–IV
Rated Mains Voltage < 1000 V
RMS
I–III
Climatic Classification 40/100/21
Pollution Degree (DIN VDE 0110/1.89) 2
CTI Comparative Tracking Index (DIN IEC 112/VDE 0303 Part 1) 175
V
PR
Input-to-Output Test Voltage, Method b, V
IORM
x 1.875 = V
PR
,
100% Production Test with t
m
= 1 s, Partial Discharge < 5 pC
2651 V
peak
Input-to-Output Test Voltage, Method a, V
IORM
x 1.6 = V
PR
,
Type and Sample Test with t
m
= 10 s, Partial Discharge < 5 pC
2262 V
peak
V
IORM
Maximum Working Insulation Voltage 1414 V
peak
V
IOTM
Highest Allowable Over Voltage 8000 V
peak
External Creepage 8.0 mm
External Clearance 8.0 mm
Insulation Thickness 0.5 mm
Safety Limit Values – Maximum Values in Failure;
T
Case
Case Temperature 15
0 °C
Safety Limit Values – Maximum Values in Failure;
P
S,INPUT
Input Power 100 mW
Safety Limit Values – Maximum Values in Failure;
P
S,OUTPUT
Output Power 600 mW
R
IO
Insulation Resistance at T
S
, V
IO
= 500 V 10
9