Drawing
301 Fulling Mill Road, Suite G 
Middletown, PA 17057 
Phone (800) 321-2343 / Fax (717) 702-2546 
www.onqlegrand.com
                         Page 2 of 4 
INSTRUCTION/INSTALLATION SHEET 
lyriQ™ Studio Local Source Input 
IS-0421 REV. O 
 ©Copyright 2008 by On-Q/Legrand All Rights Reserved. 
delay for switching back to the main audio source after the local audio source is no longer present. 
NOTE: Clockwise rotation increases sensitivity and time delay, while Counter Clockwise rotation 
decreases sensitivity and time delay. 
There is a jumper on the rear that determines whether the lyriQ™ Studio Local Source Input works in Knob 
mode or Keypad mode (see NOTE after Installation step B3). 
NOTE: The lyriQ™ Studio Local Source Input, like other On-Q/Legrand lyriQ™ Audio system 
components, is powered by the On-Q/Legrand lyriQ™ Audio Distribution Module. 
3. Installation 
Installation of the On-Q lyriQ™ Studio Local Source Input is best accomplished in two steps during new 
construction, at “Rough-in” before the drywall is installed, and at “Trim-out” after the drywall is installed and 
painted. 
NOTE: The On-Q/Legrand lyriQ™ Studio Local Source Input is typically mounted at electrical outlet 
height. Measure the height of the nearest box on the same wall that the lyriQ™ Studio Local Source Input 
will be installed and place the electrical back box at the same height. Position the cabling to maintain 
separation of any low voltage cable such as Category 5 from AC power wiring. Special applications, such 
as audio from a TV, entertainment center, or a computer, may require different heights including those 
above the chair rail, such as in the kitchen. 
A.  “Rough-in” steps: 
1.  Run Category 5 cable from the lyriQ™ Audio Distribution Module located in the Enclosure to the single 
gang box at the location that will contain the lyriQ™ Studio Local Source Input. Also run Category 5 
cable from the single gang box that will contain the lyriQ™ Studio Local Source Input to the volume 
control location (or to the second lyriQ™ Studio Local Source Input and then to the volume control 
location). 
NOTE: If optional 16/4 speaker cable is run with the Category 5 cable for potential upgrade to high 
performance keypads in the future (see Figure 3 and 4), it can be run directly from the enclosure to the 
volume control. 
B. “Trim-out” steps: 
NOTE: Always follow TIA-570-B and T568A wiring standards for installing and terminating Category 5 
cable. Failure to follow the correct wiring standard could result in damaged equipment and/or electrical 
interference issues. 
NOTE: Maintain a minimum 12” separation between Category 5 cable and any 120VAC cabling. 
1.  At the intended Studio Local Source Input location, pull the prewired Category 5 cable from the 
lyriQ™ Audio Distribution Module out of the single gang box and terminate it with an RJ45 plug and 
snap it into the RJ45 jack labeled “INPUT” on the rear (see Figure 2). 
2.  Pull the prewired Category 5 cable from the lyriQ™ Volume Control (or next Studio Local Source 




