Instruction Manual
12
Air Clean Units
Specifications
Ionizers
*1 Use the dip switches on the unit surface (connector surface) to switch between RS-422 and RS-485.
*2 Contact input: 5 mA max. ON current. Use input device of 30 V or higher withstand voltage.
225 × 205 mm
360 × 360mm 578 × 568 mm
Instruction Sheet, Sealing parts,
Mounting screws, I/O connector (XW4B-06B1-H1)
Instruction Sheet, Sealing parts,
Mounting screws, I/O connector (XW4B-10B1-H1)
Fan operation alarm output
Alarm output OFF in below cases
(
ON during normal operation
)
•
Fan not rotating
(
Including when power is OFF or on standby
)
• Trouble
• Clogged filter
(
ZN-A6112P only
)
24V DC ±10%, ripple(p-p) 10% max.
HEPA filter/ 99.99% of particles 0.3 μm and larger
ZN-A2502D ZN-A4105D ZN-A6112 ZN-A6112P
No YesYes
Item Model
Airflow level 5: 24V DC: 4.3 A max. (RMS value)/(Peak: 8 A)
Airflow level 3: 53 dB (TYP.)
Accessories
Operating status: Green/Red Air volume: Blue
None
Air outlet dimensions
Main filter/Removal rate
Power supply voltage
Current consumption
Airflow levels
Running noise
Fan motor
Indicator lamps
Filter clogging detection
External output
Applicable Ionizer Unit (Optional)
Ambient temperature range
Ambient humidity range
Applicable contamination degree
Material
Outer dimensions (mm)
Weight (Packaged)
Air volume
5 levels
• Settable by button operation
• Settable by serial (RS-422 or RS-485 *1) communications
5 levels
• Settable by button operation
• Settable by serial
(RS-422 or RS-485 *1)
communications
• Settable by ON/OFF signal input
(
3 levels
)
*2
Compact DC brushless
centrifugal blower × 2
DC brushless turbo fan × 1
ZN-J25A
Operating and storage: 0 to 40
°C (with no icing or condensation)
Operating and storage: 35 to 85% (with no icing or condensation)
ZN-J41A
250 (W) × 250 (D) × 97.5 (H)
Airflow level 5: 2.1 A max.
(RMS value)/(Peak: 3 A)
Airflow level 5: 3.5 A max.
(RMS value)/(Peak: 5.5 A)
Alarm output 1: Alarm output 1 turns OFF when one of the
following events occurs.
(Normally alarm output 1 is ON.)
(Check indicator to find out which event occurred.)
• Filter is clogged.
• Fan error
• Cleaning alarm for discharge needle (when ZN-J-series
Ionizer (sold separately) is connected)
• Discharge error (when ZN-J-series Ionizer (sold separately)
is connected)
Alarm output 2: Enabled only when ZN-J-series Ionizer
(sold separately) is connected.
• Alarm output 2 turns OFF to indicate that cleaning is
necessary for ZN-J Series discharge needles.
(Normally alarm output 2 is ON.)
Top: Antistatic plastic, Bottom: SECC
Airflow level 3: 58 dB
(
TYP.
)
DC brushless turbo fan × 1
30 VDC, 50 mA max.
Residual voltage: 1 V max. with load current of 10 mA, 2 V max. with load current of 50 mA.
2
Top: ABS, HEPA filter frame: Aluminum
410 (W)
× 410 (D) × 129.5 (H)
Approx. 5.2 kg (Approx. 8.6 kg)
Approx. 2 kg (Approx. 3.3 kg)
714.4 (W) × 654.4 (D) × 174.3 (H) (Height off installation surface: 117.3)
Approx. 12.5 kg (Approx. 17 kg)
Applicable Air Clean Unit
Power supply voltage
Current consumption
Discharge voltage
Discharge method
Static electricity removal time (Typical) *1
Ion balance (Typical) *2
Indicator lamps
External output
Functions
Ambient temperature range
Ambient humidity range
Materials
Outer dimensions (mm)
Weight (Packaged)
Accessories
ZN-A2502D ZN-A4105D
24V DC ±10%, Ripple (p-p):10% max.
300 mA max.
±7 kV max.
Variable DC discharge
5 s max.
±30 V max.
Power (green), Cleaning notice (orange flashing), Cleaning alarm (orange), High voltage error (red)
High voltage error, cleaning outputs: Output from photo MOS relay (30V DC, 300 mA max.)
Manual adjustment of ion balance, cleaning required detection, high voltage detection
Operating and storage: 0 to 40°C (with no icing or condensation)
Operating and storage: 35% to 65% (with no condensation)
Body: ABS, Needles: Tungsten
248 (W)
× 310 (D) × 45 (H) 408 (W) × 470 (D) × 45 (H)
Approx. 0.6 kg (Approx. 1.4 kg) Approx. 1.5 kg (Approx. 2.7 kg)
Instruction Sheet, Sealing parts, Mounting screws,
Connector cable for Air Clean Unit, English warning label
ZN-J41A
ZN-J25A
*1 Measurement conditions:
Distance: 300 mm
Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet
Discharging from ±1000 V to ±100 V with a charge plate monitor (150
× 150 mm, 20 pF)
Temperature: 18 to 28˚C, Humidity: 35 to 55%
Performance may not be satisfied if gases such as from solvents are in the measurement area.
*2 Measurement conditions:
Distance: 300 mm
Air Clean Unit: ZN-A Series with airflow level 5 at center of air outlet
Measured for 10 sec by a charge plate monitor (150
× 150 mm, 20 pF)
Temperature: 18 to 28˚C, Humidity: 35 to 55%
Performance may not be satisfied if gases such as from solvents are in the measurement area.
Item Model
4 to 12 m
3
/min (TYP.)
0.3 to 1.8 m
3
/min
(
TYP.
)
1 to 5 m
3
/min
(
TYP.
)