Instruction Manual
10
Clean Monitoring System
There are four ways of using the In-line Air Particle Sensor, depending on the application.
System Connection Diagram
24-VDC
power supply
24-VDC
power supply
Air Clean Unit ZN-A2502
ZN-A4105
Up to 9 Units
Standard cable length: 2 m
Standard cable length: 2 m; Power is supplied from the Air Clean Unit.
To extend, use commercially available LAN connectors (female–female, straight) and LAN cable (straight, category 5 E
or better).
Up to
10 Units
Ionizer
ZN-J25A
ZN-J41A
Realtime Clean
Air Monitor
Sensor Head
ZN-PD03
Sensor Head
ZN-PD03
Amplifier
ZN-PDA11
Calculating Unit
ZX-CAL2
Amplifier
ZN-PDA11
Interface Unit
• The air volume of the Air Clean Unit is automatically adjusted while the particle volume is measured and logged.
• The level of cleanliness can be managed and feedback controlled for more than one production process.
• Particle volumes are logged and warnings or alarms are output for set thresholds.
• Discharging can be performed with the downflow from the Air Clean Unit.
• The air volume of the Air Clean Unit is automatically adjusted while the particle volume is measured and logged.
Supplied
Connection Cable
Air Particle Sensor
Clean Monitoring System
Realtime Clean
Air Monitor
Interface
Unit
Discharging and Dust Removal System
Air Particle Sensor
Clean Monitoring System
Realtime Clean
Air Monitor
Interface Unit
Note: Required for each Air Clean Unit.
Power supply
Supplied AC Adapter
or 24-VDC power supply
Sensor Head
ZN-PD03
Amplifier
ZN-PDA12
Air Particle Sensor
Air Clean Unit
ZN-A2502
ZN-A4105
Ionizer (See note.)
ZN-J25A
ZN-J41A
Supplied Connection
Cable
Discharging and Dust Removal System
Power supply
Supplied AC Adapter
or 24-VDC power supply
To extend, use commercially available LAN connectors (female–female, straight) and LAN cable (straight, category 5E or better).
ZN-SFW11
ZN-SFW11
ZN-SFW12
Use a commercially available LAN cable (straight, category 5 E or better) if more than one
Air Clean Unit is to be connected.
Measurement and Logging of Particle Volumes
Clean Air Supply and Discharging
Direct Clean Sensing Systems
Multi-Clean Sensing Systems
Note: When using the Ionizer in combination with an Air Clean Unit, be sure to specify
an applicable model (e.g., ZN-J25A).
Air Clean Unit
ZN-A2502
ZN-A4105
Ionizer (See note.)
ZN-J25A
ZN-J41A
Supplied Connection
Cable
Note: When using the Ionizer in combination with an Air Clean Unit, be sure to specify
an applicable model (e.g., ZN-J25A).
Power supply
Supplied AC Adapter
or 24-VDC power supply
• • • • •
• • • • •
• • • • • •