User's Manual
V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
74 of 110
©OMRON CORPORATION 2006
(2) Get operation of reader (GETO: GET Operation)
This command allows the Reader/Writer to read the current operation conditions. Even after setting
operation command (SETO) is executed, the old information shall be read out unless the reboot is
completed.
Command GETO (S) param1 (S) ... param n<LF>
Specifies a single setting item. (not required ‘-‘ before the item)
* Multiple setting items cannot not be specified.
Response GETO (S) param1=value1 (S)<LF>
*(S) Space Character
Example 1) When executed command is read at startup,
[Tx] GETO iec<LF>
[Rx] GETO0000 iec=" rdid -ant 122322 -tmo 100"<LF>
Example 2) When Input 1 function setting is read,
[Tx] GETO in1<LF>
[Rx] GETO0000 in1=1 0 "rdid -ant 122322 -tmo 100"<LF>
Example 3) When Output 1 function setting is read,
[Tx] GETO ot1<LF>
[Rx] GETO0000 ot2="31 0 mbk 1 dpt 2 dat=XXXX0000"<LF>