3.1.5.3 Reader/Writer operation conditions
Specifying following option in the operation setting command (SETO) or operation read command
(GETO) enables to set or read the Reader’s operation conditions.
Reader Network Settings (GETR/SETR)
Code Content User setting value Factory Settings
CLI Receiver of response
after command
execution.
0:None
1:Ethernet
2:RS-232C
1:Ethernet
IEC Initial Executed
Command. Executed
command at startup.
Executed command sequence(実行されるコ
マンド)
Example
RDID –seq SOC –tmo 500
(None)
IN1
Input port #1 function
setting
Function
0:None
1:Command execution
Timing
0:Startup
Command
Example
1 0 “RDID –seq SOC –tmo 500”
(None)
IN2 Input port #2 function
setting
Same as IN1 (None)
IN3 Input port #3 function
setting
Same as IN1 (None)
IN4 Input port #4 function
setting
Same as IN1 (None)
OT1
Output port #1 function
setting
Timing
00:None
11:RUN output
12:ERR output
20:COM output
2n:ATn: Current antenna(s) (n=1~4)
31:NML (evaluated normal completion)
32:ERR (evaluated completion with error
occurring)
Output time
10〜2550 (ms)
0:Status kept until upcoming evaluation.
-Output time is effective only for NML/ ERR
setting
Evaluation condition
* Refer to the following list.
(None)
ng
OT2 Output port #2 function
setting
Same as OT1 (None)