User's Manual

V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
67 of 110
©OMRON CORPORATION 2006
3.1.5.2 Information of the Reader , Status of the Reader function
To setting type of the Reader information and conditions of the Reader function, following items shall be
specified in the SET Reader command (SETR) and GET Reader command (GETR). Specifying following
option makes setting or read the Reader/Writer function. Information of the Reader is available only for reading
data.
Reader Basic information (GETR)
Code Content Fixed Value (=Factory Settings)
MFT ManuFacTurer OMRON Corporation
TYP TYPe of the Reader V750-BC50C04-US
FWV FirmWare Version xxxx-xxxx-xxxx-x
SER SERrial number xxxx xxxx xxxx xxxx
MAC MAC address 00:00:0A:89:x3:xx
Reader Status (GETR)
Code Content Reader Status
ATS AnTenna Status
Connected Antenna
????????
TTK Transition Time from Kick hhhh:mm:ss
-Min: 0000:00:00
-Max: 9999:59:59
Reader Basic information (GETR/SETR)
Code Content User Setting Value Factory Settings
RNM Reader NaMe -Min: 63charactors , ASCII
-Max: 63charactors , ASCII
(None)
RRL Reader’s RoLe -Min: 63charactors , ASCII
-Max: 63charactors , ASCII
(None)
Reader Network Settings (GETR/SETR)
Code Content User setting value Factory Settings
Input Select
PRT Ethernet PoRT
2 ports are used; specified port
(command control) and
specified port +1(Web
function).
-Min: ????
-Max: ????
7090
LHN LAN Host Name
Sent to DHCP server when IP
is acquired.
-Min: 0charactor
-Max: ?charactors
V750-BC50C04-US
LDN LAN Domain Name
Sent to DHCP server when IP
is acquired.
(None)
DHE DHCP Enable
0:Disable
1:Enable
0:Disable
LIP LAN IP Address
IP address when using static
IP address
xxx.xxx.xxx.xxx 192.168.1.200
LNM LAN Net Mask
Net Mask when using static IP
address
xxx.xxx.xxx.xxx 255.255.255.0
LGW Default Gateway
IP Address for the Gateway
xxx.xxx.xxx.xxx 192.168/254