User's Manual

V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
58 of 110
©OMRON CORPORATION 2006
shall be specified in 32-bit hexadecimal format as below. (0x not required)
Format: XXXXXXXX ... XXXXXXXX 32bit 単位との内容を追記!!
X: 0 to 9 , A to F
Lock code
When Lock command is executed, this code shall be specified depending on
the type of lock.
For GEN2 system, 10-digit Lock value shall be specified with 0, 1, * (0 and 1
mean Action and * means MASK) for following five areas; Kill pwd, Access
pwd, EPC memory, TID memory, and User memory.
Format: XXXXXXXXXX
X: 0 or 1 or * (0:Off , 1:On , *:do-nothing)
chr. 1 2 3 4 5 6 7 8 9 10
Kill pwd Access pwd EPC memory TID memory User memory
Action
Fields
pwd
read/
write
perma
lock
pwd
read/
write
perma
lock
pwd
write
perma
lock
pwd
write
perma
lock
pwd
write
perma
lock
Option shall be specified with values following the code that indicates option type.
Option Details
Code Item Specified Value Default Value
-seq Communication
seq
uence
Specifies the communication sequence according to
the operating conditions. For “Read ID” command, all
parameters can be specified. For other commands,
only SOC can be specified.
SOC: Single Once
SRP: Single Repeat
MOC: Multi Once
MRP: Multi Repeat
-seq SOC
-ant Antenna number Can specify the order of antenna to operate from first
to 9thwith figure of 1, 2, 3, and 4. The figure 1 to 4
means antenna’s identical number. If an antenna is
specified multiply, the antenna executes sequence
multiply depend on the order.
Format: X ... XXXXXXXXX (Max 9 characters)
X: 1 to 4
-ant 1
-tmo Timeout
Specifies time parameter for communication process
with 0 to 2550 in decimal number. The numbers after
rounding down to the 10 is added ms as a specified
value (the least significant digit is always “0”). If the
communication sequence is SOC/MOC, the specified
value is the communication time. If the value is
specified 0 (zero), communication process will
continue until STOP command is executed. If the
communication sequence is SRP/MRP, the specified
value is maximum time between response (0 can’t be
specified for SRP/MOC/MRP).
0, 10...2550 (ms)
-tmo 250