User's Manual
V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
54 of 110
©OMRON CORPORATION 2006
7A 00
Address
specification
error
Specifying Bank/Address in the tag memory is
incorrect and command can not be executed.
7B 00
Data write error During the data write into the detected tag, sufficient
power is not supplied to the tag.
1x
Antenna
detection error
At the R/W starts up, an appropriate antenna has not
been connected to the specified antenna port.
7C
2x
Antenna error Error occurred with the antenna connected to the
specified antenna port (even though the antenna is
detected normally when start up).
7E 00
Lock error When data write or read command is sent for the
locked area. It depends on the tag’s chip
specifications. (For Monza chip, when these command
are sent for Lock Bit of User Memory because this
area does not exist.)
7F xx
Tag error The tag has been rejected the command process.
System
error
9A xx
Hardware error An error that blocks command execution has been
detected in the hardware (such as malfunction of inner
circuit or temporally execution error caused by noise).
Response Code の x は、0~9,A-F のいずれかの文字が入ることを示しています。