User's Manual
V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
53 of 110
©OMRON CORPORATION 2006
3.1.3 Response Code List
Response code consisting of four digit figures represents the result of the command execution. Response code
helps you speculate a cause of the occurred error.
Response Code List
Response Code
Category
Main Sub
Response
Name
Description
Normal end
00 00
Normal end The received command ended normally with no error.
10 00
Parity error A parity error has occurred in one of the characters of
the command frame (For only RS-232C).
11 00
Framing error A framing error has occurred in one of the characters
of the command frame (For only RS-232C).
12 00
Overrun error An overrun error has occurred in one of the characters
of the command frame (For only RS-232C).
13 00
FCD error The command frame has an incorrect FCD (Only for
RS-232C).
0x
Command
code error
Incorrect command has been received. The response
code is ICMD.
1x
Command
parameter error
Command parameter is incorrect.
14
2x
Command
option error
Command option is incorrect.
15 0x
Process error Specified command can not be executed.
Ex1. Caused by executing a communication command
when the last command is being executed
Ex2. Caused by incorrect setting of filtering condition.
Command
error
18 00
Frame length
error
A command received from the host exceeds the
receive buffer (256 Bytes).
1x
Communication
error
During the transaction after tag detection,
communication error or process time out has occurred,
and consequently the transaction can not be
completed normally.
Specified password does not match to the password of
the target tag.
Tag
communicat
ion error
70
2x
Communication
error
During the transaction after tag detection,
communication error or process time out has occurred,
and consequently the transaction can not be
completed normally.
* In the case of ID write / Data write, a part of data in
the tag may have been written.