User's Manual
V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
41 of 110
©OMRON CORPORATION 2006
2.3 Communication
2.3.1 Communication Process
Combining following process options, suitable communication procedures can be specified for your
application.
■
Process list
Item Specifications Note
ID read Reads tag’s ID data.
ID write Writes ID data into the tag.
Data read Reads tad data (including password).
Data write Writes data (including) into tag.
Lock Enables lock function in the tag.
Process contents
(Command)
Kill Disables tag permanently.
Single Once Executes a fixed count or specified period.
Single Repeat Repeat transaction until termination has
been instructed.
Multi Once Executes a fixed count or specified period.
Communication
sequence
(Option)
Multi Repeat Repeat transaction until termination has
been instructed.
Antenna
specification
(Option)
Antenna Sequence1-4 Sets maximum 9 antennas.
(GEN2)Session specified (Once
or Repeat)
S0/S1/S2/S3
UHF Power(Port1,2,3,4)
Set each port separately.
Communication mode Normal/(MRM)/DRM
Reads only selected tags suitable
for pre-specified data conditions.
Objective tags are the tags that meet the
conditions specified with Select Command
prior to communication sequence.
Communication
parameter
(Setting)
1. Prevention of response
duplication.
2. Prevention of reread.
3. Omission of no tag response.
Filtering Filtering function
Smoothing Smoothing function