1.4 Specifications
Electrical
Reader
UHF operating frequency ..............................................................902.75–927.25MHz
Input voltage............................................................................................. 12Vdc,
2.3A
RF connector type .................................................................................. Reverse-TNC
Separate Power Supply
Input voltage............................................................... Nominal 100–240Vac, 50/60Hz
AC line current........................................................................... Nominal 0.5A at 120V
Output voltage ................................................................... Nominal 12Vdc, 2.5A peak
Antenna
Operating frequency................................................................................902–928MHz
V.S.W.R............................................................................................................ < 1.5 :1
Polarization............................................................................................Circular / Liner
Impedance......................................................................................................... 50ohm
Cable length .............................................................................................. 30cm(11.8’)
RF connector type ........................................................................................ N-Female
Environmental
Reader
Operating temperature: .....................................................-10° to 55°C (14° to 122°F)
Storage temperature: .......................................................-25° to 65°C (-13° to 149°F)
Relative humidity: .........................................................25 to 85%RH non-condensing
Antenna
Operating temperature: .....................................................-10° to 55°C (14° to 122°F)
Storage temperature: .......................................................-25° to 65°C (-13° to 149°F)
Relative humidity: .........................................................25 to 85%RH non-condensing
Mechanical
Reader
Dimension ..................................................... 246 x 215 x 43.5mm (9.7 x 8.5 x 1.7 in)
Weight ................................................................................................... 1.4kg (3.1 lbs)
Protection ..............................................................................................................IP50
Antenna
Dimension .................................................... 256 x 256 x 57mm (10.1 x 10.1 x 2.3 in)
Weight ................................................................................................... 1.0kg (2.3 lbs)
Protection ..............................................................................................................IP50