User's Manual
V750 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
20 of 110
©OMRON CORPORATION 2006
1.3.3 Connect the Reader
Interface name and function
Note: MAC Address is displayed on the lower part of RJ-45 Ethernet port.
Name Function Connector specifications
Antenna port
ANT1- ANT4
Connects with UHF mono-static type antenna
specified by OMRON with attachment cables. Max 4
cables can be connected to.
Reverse TNC
Ethernet port
ETHERNET
Connects with the host by a commercially available
10/100Base-T cable.
RJ-45
LED Left: Link, Right: Act
RS-232C port
RS-232C
Connects with the host by a commercially available
cable for DOS/V RS-232C.
D-SUB 9pin (male)
Inch screw (#4-40)
Input/Output port
IN 1,2,3,4,C
OUT 1,2,3,4,C
4 Inputs: connects with the sensor that works as a
trigger signal for communication start.
4 Output: connects with the light or actuator that is
driven by output signal.
MC1.5/10-SFT-3.81 (produced
by PHOENIX CONTACT
GmbH & Co.KG).
DC Power input
POWER DC12V
Connects with the attachment AC adaptor to receive
+12V electric power.
* Extension of AC adaptor cable is not allowable.
Exclusive connector
Control port
CTRL PORT
For future expansion.
Exclusive connector
Mode switch
(Not indicated)
Pushing this button for 1 second or more makes the
system rebooting with default setting, which will be
useful in case of system error or setting unknown.
-
Ethernet
RS-232C I/O
p
ort
Mode switch
DC power
input
Control port
Antenna port
Mono-Static x 4
LED Indicators