User's Manual
V740 RFID READER/WRITER, ANTENNA 2006-06, REV.C
OPERATION MANUAL
105 of 110
OMRON CORPORATION 2006
5.2 Communications Time
The following charts show communication time on each protocol. It is influenced on practical matters, for
example radio noise, distance between tags, materials tags are on and other environmental matters.
These charts are generated by plotting and linking average of actual communication time on every 5 tags.
Communication time is measured in shielded room with one reader, so that no reflection and no interference
are considered.
You can refer these charts on determining time out value of RQL command. But you must keep in mind actual
communication time on your environment may not correspond to these charts because of the reasons already
described.
GEN2 Tags
Actual Communication Time (ms)
250
200
150
100
50
0
Number of Tags
5 10 15 20 25 30 35 40
N
umber of Tags:0〜200
DRM ON/OFF
Timeout 値を決定する為のグラフで
あるにもかかわらず実フィールドで
使用するための値としていない。