Manual
3 Instruction Execution Times and Number of Steps
3-10
CP1E CPU Unit Instructions Reference Manual(W483)
Subroutine Instructions
Instruction Mnemonic
FUN
No.
Length
(steps)
ON execution
time (µs)
Conditions
SUBROUTINE CALL SBS 091 2 6.6 ---
SUBROUTINE ENTRY SBN 092 2 2.6 ---
SUBROUTINE RETURN RET 093 1 3.1 ---
Interrupt Control Instructions
Instruction Mnemonic
FUN
No.
Length
(steps)
ON execution
time (µs)
Conditions
SET INTERRUPT MASK MSKS 690 3 15.1  Set
15.1 Reset
CLEAR INTERRUPT CLI 691 3 14.9  Set
18.0 Reset
DISABLE INTERRUPTS DI 693 1 8.5  ---
ENABLE INTERRUPTS EI 694 1 8.9  ---
High-speed Counter and Pulse Output Instructions
Instruction Mnemonic
FUN
No.
Length
(steps)
ON execution
time (µs)
Conditions
MODE CONTROL
INI
880 4
46.0  Starting high-speed counter comparison
31.8  Stopping high-speed counter comparison
48.7  Changing pulse output PV
35.2  Changing high-speed counter PV
27.2 Stopping pulse output
13.0  Stopping PWM(891) output
HIGH-SPEED COUNTER PV
 READ
PRV
881 4
40.0  Reading pulse output PV
35.0  Reading high-speed counter PV
37.2  Reading pulse output status
32.6  Reading high-speed counter status
24.5  Reading PWM(891) status
36.5  Reading high-speed counter range 
comparison results
29.1  Reading frequency of high-speed counter 0
COMPARISON TABLE LOAD
CTBL
882 4 69.3  Registering target value table and starting 
comparison for 1 target value
116.3  Registering target value table and starting 
comparison for 6 target values
126.6  Registering range table and starting com-
parison
46.3  Only registering target value table for 1 
target value
93.3  Only registering target value table for 6
target values
122.5  Only registering range table
SPEED OUTPUT
SPED
885 4
69.2 Continuous mode
74.0 Independent mode
SET PULSES
PULS
886 4
44.1 
---
PULSE OUTPUT
PLS2
887 5
97.6 
---