Manual
2-351
2 Instructions
CP1E CPU Unit Instructions Reference Manual(W483)
 Step Instructions
2
 SNXT/STEP
(3) Parallel Execution
SW1
SW2
SW3
SW4
SW6
SW5 SW7
Process C
Process A
Process D
Process B
Process E
Conveyer A
Conveyer C
Conveyer D
Conveyer B
Conveyer E
0.05(SW7)
0.02(SW3)
0.03(SW4)
Process A
Process E
End
Process C
Process B
Process D
0.04(SW5 and SW6 both ON)
0.01(SW 1 and SW2 both ON)
Explanation of operation
(1) SW1, SW2 ON:
 Conveyor (A) operates
Work (A) operates
 Conveyor (C) operates
Work (C) operates
(2) SW3 ON:
 Process (A) stops
 Conveyor (B) operates
Work (B) operates
(3) SW4 ON:
 Process (C) stops
 Conveyor (D) operates
Work (D) operates
(4) SW5, SW6 ON:
 Process (B) stops
 Process (D) stops
 Conveyor (E) operates
Work (E) operates
(5) SW7 ON:
 Process (E) stops
Additional Information
The STEP instruction turns all outputs in its process OFF when ON 
changes to OFF.
Process A
Process C
Process B
Process D
Process E
Note  When processes (B) and (D) are in operation and SW5 and 
SW6 turn ON, it is judged that processes (B) and (D) are finished.
Execution of SNXT W0.04 turns OFF the outputs of process 
(B) and W0.03 turns OFF.
STEP W0.03 judges ON to OFF and turns OFF the outputs of 
process (D).
Process A 
started.
Process C 
started.
Programming for process A
Process A 
reset.
Process B 
started.
Used to 
turn off 
process D.
Process E 
started. 
Programming for process C
Process C 
reset.
Process D 
started.
Programming for process D
Programming for process E
Process E 
reset.
Programming for process B
W0.03
0.04(SW5, SW6)
0.01(SW1, SW2)
0.02(SW3)
0.03(SW4)
0.05(SW7)
W0.04
STEP
W0.01
SNXT
W0.02
SNXT
W0.00
STEP
W0.02
SNXT
W0.04
SNXT
W0.03
STEP
W0.00
SNXT
W0.01
STEP
W0.03
STEP
W0.04
STEP
SNXT
W30.0
W0.03