NT31 NT31C Programmable Terminals Setup Manual
Appendix IRelationship between System Program and Hardware
276
Combining a -V1 Version and -V2 Version
Hardware
NT31-ST121-EV1
NT31C-ST141-EV1
NT31-ST121-EV2
NT31C-ST141-EV2
System program Ver. 2.0 or Ver. 2.1
The following functions (new functions supported by the -V2) cannot be used:
Additional data areas accessible in CS1-series PCs
The CS1-series high-speed 1:N NT Link
Interlock function that controls touch switches, numeral inputs, and character string inputs
Mathematical function
Device Monitor function
NT30/620 compatible mode
Expanded capabilities for label (guide character) displays, including multiple lines of text, ON/OFF switching
displays, numeral memory table displays, and character string memory table displays
System program Ver. 3.0
All of the functions described in the Setup Manual and Reference Manual can be used.
* The system program’s version can be checked from the System Menu.
Combining a -V2 Version and Version without a -V Suffix
Hardware
NT31-ST121-E
NT31C-ST141-E
NT31-ST121-EV2
NT31C-ST141-EV2
System program Ver. 1.0
The following functions cannot be used
Analogue meter
High-definition font display
Installation of system programs using memory unit
Connection to Mitsubishi PLCs
Memory link
Window control from the host
Multiple display of window screens
Moving a window
Additional data areas accessible in CS1-series PCs
The CS1-series high-speed 1:N NT Link
Interlock function that controls touch switches,
numeral inputs, and character string inputs
Mathematical function
Device Monitor function
NT30/620 compatible mode
Expanded capabilities for label (guide character)
displays, including multiple lines of text, ON/OFF
switching displays, numeral memory table displays,
and character string memory table displays
The following functions cannot be used
Analogue meter
High-definition font display
Connection to Mitsubishi PLCs
Memory link
Window control from the host
Multiple display of window screens
Moving a window
Additional data areas accessible in CS1-series PCs
The CS1-series high-speed 1:N NT Link
Interlock function that controls touch switches,
numeral inputs, and character string inputs
Mathematical function
Device Monitor function
NT30/620 compatible mode
Expanded capabilities for label (guide character)
displays, including multiple lines of text, ON/OFF
switching displays, numeral memory table displays,
and character string memory table displays
* Installation of system programs using memory unit
is possible
System program Ver. 3.0
The following functions cannot be used
Installation of system programs using memory unit
High-definition font display
All of the functions described in the Setup Manual and
Reference Manual can be used.
* The system program’s version can be checked from the System Menu.