Instruction Manual

37
Motion Control Modules Section 2-4
I/O Specifications
Built-in General-purpose I/O
2-4 Motion Control Modules
Motion Control
Module
FQM1-MMP21 (Pulse I/O)
RUN output 1 (when CJ1W-PA205R used)
Individual func-
tions
Serial communica-
tions
Peripheral port: Peripheral bus (Toolbus), Host Links, NT Links
Built-in RS-232C port on Coordinator Module: Peripheral bus (Toolbus), Host Links,
no-protocol communications, NT Links, and Serial PLC Links (slave).
Built-in RS-422A port on Coordinator Module: Servo Driver interface
Item Specifications
Item Specifications
Inputs Number of inputs 16
Input voltage 20.4 to 26.4 V
Input response Inputs for normal input (16 points):
ON delay time: 100 µs
OFF delay time: 1 ms max.
8 points/common
Outputs Number of outputs 8
Output type NPN transistor
Switching capacity 4.5 to 30 V DC, 0.3 A per output
ON delay time 0.1 ms max.
OFF delay time 1 ms max.
Item Specifications
I/O Pulse I/O Pulse inputs: 2 (compatible with Servo Drivers with absolute encoders)
Pulse outputs: 2
40-pin connector
General-purpose
I/O
General-purpose inputs: 12
General-purpose outputs: 8
26-pin connector
Functions Pulse outputs The following operations are supported:
Speed control (fixed, acceleration, deceleration)
Positioning (Fixed-speed positioning; trapezoid, acceleration/deceleration positioning,
and deceleration positioning)
Speed control according to the present position (pulse output target value comparison or
range comparison)
Electronic cam operation (Positioning according to the rotation position of the real or vir-
tual axis.)
One-shot pulse output (Output ON only for specified time. minimum increment: 0.01 ms)
Time measurement using pulse counter (minimum increment: 0.0001 ms )
Pulse inputs High-speed counters: Phase, Increment/decrement, Pulse + direction inputs (50 kHz/1
MHz), or phase differential (50 kHz/500 kHz; phase differential × 4, 2 MHz )
High-speed counter can be started/stopped using counter start bit.
Changes in high-speed counter present value can be measured.
High-speed counter frequency can be measured.
Program Program capacity 5 Ksteps