Data Sheet

2
G8P G8P
COIL DATA
Rated Rated Coil Pick-up Dropout Maximum Power
voltage current resistance voltage voltage voltage consumption
(VDC) (mA) ()
% of rated voltage
(mW)
5 185 27 75% max. 10% min. 120% max. Approx. 900
993 97
12 77 155
24 36 660
48 19 2480
110 9 12400
Note: The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of ±10%.
Contact resistance 100 m max. (measured with 5 VDC, 1 A)
Operate time 15 ms max.
Release time 10 ms max.
Insulation resistance 10 M min. (at 500 VDC)
Dielectric strength 2,500 VAC, 50/60 Hz for 1 minute (coil to contacts),
1,500 VAC, 50/60 Hz for 1 minute (between contacts)
Impulse surge withstand 6,000 V between coil to contacts (1.2 µs/50 µs & 100 kHz ring wave per IEC 1000-4-12)
Vibration Mechanical durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 2 hours
Malfunction durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 5 minutes
Shock Mechanical durability 1,000 m/s
2
(approx. 100 G)
Malfunction durability 100 m/s
2
(approx. 10 G)
Ambient temperature -55° to 105°C (-67° to 221°F)
Humidity 45% to 85% RH
Service life Mechanical 10 million operations minimum
Electrical 100,000 operations at rated load (minimum)
CHARACTERISTICS
Note: Data shown are of initial value. Operate and release times excluding bounce.
CHARACTERISTIC DATA
Maximum switching capacity
SPST-NO SPDT
Rated operating current (A)
Rated operating current (A)
Rated operating voltage (V) Rated operating voltage (V)