Datasheet

80
PCB Power Relay – G6RN
Coil Ratings
Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC
Rated current 44 mA 18.3 mA 9.2 mA 5.2 mA
Coil resistance 114 1 655 1 2,620 1 9,210 1
Must operate voltage 70% max. of rated voltage
Must release voltage 10% min. of rated voltage
Max. voltage 110% of rated voltage at max. temperature (at 85˚C)
Power consumption Approx. 220 mW Approx. 250 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C..
Contact Ratings
Load Resistance load (cosø = 1)
Rated load 8 A at 250 VAC: 5 A at 30 VDC
Rated carry current 8 A
Max. switching voltage 250 VAC; 30 VDC, (400 VAC) (see note)
Max. switching current AC 8 A; DC 5 A
Max. switching power 2,000 VA; 150 W
Failure rate 5 VDC 10 mA
(reference value) (for gold plating 0.35 µ min.)
Note: Electrical life expectancy is reduced.
Characteristics
Operate time Approx. 6 ms
Release time Approx. 3 ms
Max. operating frequency Mechanical: 36,000 operations/hr
Electrical: 360 operations/hr (under rated load)
Insulation resistance 1,000 M1 min. (at 500 VDC)
Dielectric strength 4,000 VAC between coil and contacts
1,000 VAC between contacts
Creepage/clearance 8 mm min. between coil and contacts
Vibration resistance Malfunction: NO: 10 to 55 to 10 Hz, 0.75mm single amplitude (1.5mm double amplitude)
NC: 10 to 55 to 10 Hz, 0.4mm single amplitude (0.8mm double amplitude)
Shock resistance Destruction: 1,000 m/s
2
Endurance Mechanical: 10,000,000 operations min.
Electrical: Approx. 100,000 operations
Ambient temperature Operating: -40°C to 85°C (with no icing)
Ambient humidity Operating: 5% to 85%
Weight Approx. 9 g
Protection class II according to VDE0106 Part 1
Insulation class C/250, B/380 according to VDE0110
Specifications